Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C6600S
25
a) Make sure that the pins the 24-pin are closed;
b) Turn on the chiller and check leakage. If there is no water leakage, turn off the chiller
and wait for the laser to turn on.
c) Turn on the air switch and release the emergency stop switch.
d) Let the chiller work;
e) Turn on the key switch and start the laser.
4.7
Functions of the clientware
The RFL-C6600S clientware communicates with the main control board through UDP when
it is working. Through the background program running in the software and the human-computer
interaction operation, the laser parameters are read and set and the control functions are realized.
The interface displayed by the software is divided according to functional categories, including
control, alarm, about, language selection, authorization, working mode selection and other pages.
Figure 11 The clientware interface
4.7.2 The control interface