When the water quality of the laser cooling system is poor (more impurities), the laser
water path is easy to be blocked, causing flow alarm or high temperature alarm,
resulting in laser shutdown. In serious cases, the laser waterway will be scrapped.
Therefore, RFL-C6600S laser is equipped with water inlet filter module, as shown in
Figure 4.
Figure 4 The inlet filter module
When the laser is installed and used, firstly connecting the water inlet filter module
with the water outlet of the customer's on-site cooling water system according to the
water flow direction indicated by the arrow in Figure 4, and then connect the water
inlet filter module with the water inlet of the RFL-C6600S laser, as shown in Figure 5.
Figure 5 The water inlet filtration module is connected to the watercooling system
When the laser is in use, cleaning the Y-type filter of the inlet water filter module
periodically according to the water quality of the cooling water system (openning the
nut cover of the Y-type filter, taking out the filter screen, cleaning it, reinstall it, and