Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C6600S
21
13
Analog
Output Power
Monitor
AOUT
Analog
Output
0-8V
DC
11mA
100µs
Analog Output 0-8
VDC
(
Refer to factory
inspection report for
details
)
14
Isolated
Analog Com
GND1
Return
---
---
---
Return for signals on pins
12, 13,19,22,23,24
15
Mod
MOD+
Digital
Input
5-24
VDC
6 mA
20µs
5 -24 VDC Input
16
Modulation-
MOD—
Return
Return for signal on pin 15
17
Guided Laser
Control
RED-LA
SER
Digital
Input
5-24
Vdc
6 mA
120ms
Positive edge activates
emission in REM mode
18
Emission
Enable
LAS—C
Digital
Input
5-24
VDC
6 mA
1ms
Positive edge activates
emission in REM mode
19
System
error
(
ERR
OR
)
S-ERR
Digital
output
24VD
C
100m
A
120ms
High=System error
20
System
Common
GND2
Return
Return for pin 17
、
18
、
21
21
Error RESET
RESET
Digital
Input
5-24
VDC
6 mA
120ms
Rising edge reset (the
resettable alarm)
22
READY
READY
Digital
output
24VD
C
100m
A
120ms
High=Laser is ready
23
Power
started
POWER
Digital
output
24VD
C
100m
A
120ms
High=The main power
supply is started
24
Laser
emission
LASER
Digital
output
24VD
C
100m
A
100ms
High=Laser is emission
Caution: Please check the control voltage level and ensure that the level is in
accordance with the requirements. Over voltage and voltage ripple may damage the
product.
The Service Security Interface is pin 2-3 and pin 1-4 of CTRL-INTERFACE.If the pin 2-3
and pin 1-4 are disconnected, the laser will immediately stop emitting light, and the laser Ready
signal output will change to low level. Be sure to short-circuit pin 2-3 and pin 1-4 before using
the laser. If it is not short-circuited, the laser will display InterLock alarm after power-on.