Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL- RFL-C6600S
19
d)
WATER:
Pipe connectors, the inlet and outlet for cooling water to flow in and return.
(See Table 5 for the laser model and corresponding water pipe size for cooling system
requirements)
e)
ETHERNET:
Ethernet interface. It can provide remote control and storage alarm
information for the laser.
f)
DRAIN
:
The built-in dehumidifier has a drainage interface, the built-in dehumidifier
works to condense the water and moisture inside the cabinet into water droplets for
discharge.
4.3
Power Connection
CAUTION:
Before connecting the product to AC supply source, you must
check for sure that the AC supply you will apply is in accordance with the
specifications provided in Table 2 or 4.
Table 6 Power Connection Requirements
Model
RFL-C6600S
Supply Source
380±15% V AC 50/60Hz
Power Cord
One End of Power Cord
8 wires, each 2 wires are multiplexed, and the diameter of single wire
is 4mm
2
,Four wires labeledL1
,
L2
,
L3and PE.
Sign Description
L1
,
L2
,
L3-> Phase Line
PE-> Protective Earth
Note
One end of the power cord is a plug, insert it into the socket 'AC
INPUT' on the rear panel. Notice that the plug is wrong-side
preventing. After inserting it, lock it with the lever.