Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C100~RFL-C2000S
37
PIN 7-9 of the DB25 control interface is applied to 24V (enable hardware
emission);
Send the start or stop emitting command (enable hardware emission) to control the
emission by the PC software;
9)
The laser is controlled by the user's "modulation" signal provided by the external MOD
interface
See 4.8 to get the process of laser shutting down.
4.7.4
AD mode
When PIN 7-9 of the DB25 control interface is applied to 24V, the laser enters the external
AD mode, and the power of the laser is controlled by the voltage obtained by PIN 22-25 of the
DB25 interface connector (1V-10% power, 10V-100% power).
When PIN 7-9 of the DB25 control interface is applied to 0V or left floating, the power of
the laser is set by serial port or Ethernet.
4.7.5
Control sequence diagram
CW Mode
——
duty=100%
power
ready
ALARM
Laser
on/off
EMON/
EMOFF
laser
>10s
>1ms
>1ms
<20us <20us
Figure 27 Control sequence diagram of CW mode