Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C100~RFL-C2000S
42
The alarm is generated when the emission of the laser cannot reach the
set value. Power error occurs only when the laser is emitting.
Solution:
Restart the laser, if this error continues to occur, please contact Raycus.
ACDC1 Alarm
Instruction:
ACDC1 Error, failure of the laser power supply or sudden power
failure of the power supply system may cause an alarm.
Solution:
Check if the input AC voltage is normal. Restart the laser, if this error
continues to occur, please contact Raycus.
ACDC2 Alarm
Instruction:
ACDC1 Error, Over current or overvoltage inside the laser may
generate this error.
Solution:
Check if the input AC voltage is normal. Restart the laser, if this error
continues to occur, please contact Raycus.
T1/T2 Alarm
Instruction:
Low temperature/high temperature alarm of the laser. The sensor in the
laser detects an abnormal temperature inside the laser. A
high-temperature / low-temperature error occurs when the temperature
at the monitoring point exceeds the set upper / lower limit.
Solution:
High temperature alarm, please check if the water-cooling system is
normally working, the water temperature is set correctly, and the water
connection is correct. When the water cooling system works normally
and the water temperature drops below 30°C, restart the laser. If the
alarm continues, please contact Raycus.
Low temperature alarm, please check if the actual water temperature of
the water is too low. In addition, a low ambient temperature may also
cause a low temperature alarm when the laser is cold. Please wait until
the water temperature of the water rises above 10°C. If the alarm
continues, please contact Raycus.
Hum Alarm
Instruction:
The Hum Alarm of the laser, the internal temperature of the laser
detects that the current water-cooled plate temperature is lower than the
internal dew point temperature, and there is a risk of condensation.
Solution:
Immediately stop using the laser. For RFL-C100~RFL-C1000, please
improve the working environment and after the ambient temperature is