Wuhan Raycus Fiber Laser Technologies Co., Ltd
U
ser Guide of 1000W CW laser
Raycus User Guide | Common Alarms and solutions
37
Table12 Error instructions and possible solutions
Alarm message
Error instructions and possible solutions
System Timer
Alarm
Instruction:
Internal clock abnormal
Solutions:
When this alarm occurs, please contact Raycus directly
Laser On Button
Alarm
Instruction:
This alarm occurs when the light exit button on the front panel
of the laser has been pressed before powering on
Solutions:
When this alarm occurs, please power off the laser and make
the light enable button pop up, and then power on the laser
again to cancel the alarm. If the alarm continues to occur,
please contact Raycus.
Inter Lock Alarm
Instruction:
Occurs when the laser InterLock is disconnected
Solutions:
Short the InterLock pins. If this error continues to occur, please
contact Raycus.
Current Driver
Alarm
Instruction:
Internal constant current driver is error
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.