17
7) Please handle the laser output cable carefully, and do not receive
vibration during the installation and disassemble.
8) Make sure the environment is clean, or the output head may be
shall not be less than 20cm in the non-working state (such as transport
and storage). The minimum bending radius should not be less than 30cm
when the laser is working.
CAUTION: All the cables can only be connected when
power supply is off. Hot plug may damage the device.
Ensure that there are no fiber bends in radius less than 30cm
when the product is installed. Avoid excessive twisting and
tight bends during the robotic arm movements.
Tight bends will damage the laser delivery system.
Before the laser output cable is assembled, the lens and the
cutting head cavity must be clean and free of pollution.
Keep the protective cap properly, prevent it from
contamination; Or the aperture will be contaminated when
capped.
contaminated. It is prohibited to use fan during installation, which will
cause dust in the air.
9) The minimum bending radius
of the transmission cable of the laser