2.8
Installation Procedure
a) Check if the power supply has the correct voltage (48VDC±10%), and
the earth line is connected, make sure it is firm and reliable;
b) Place the product in an appropriate position, immobilize it if
necessary;
c) Connect the power cable and control cable to the product when power
supply is OFF;
d) Check the output head and clean it if necessary. This procedure must
be performed by Raycus personnel or person authorized by Raycus. Make
sure the environment is clean, or the output head may be contaminated.
It is prohibited to use fan during installation, which will cause
dust in the air;
e) Prevent the delivery cable from treading, pinching or excessive
bending during installation.
CAUTION: All the cables can only be connected when power supply is off.
Hot plug may damage the laser.
CAUTION: Ensure that there are no fiber bends with radius less than 20cm
when the product is installed. Avoid excessive twisting and tight bends
during the robotic arm movements. Tight bends will damage the laser
delivery system.
When the product is in storage, the bending radius of the delivery cable
should be more than 20cm.
CAUTION: Avoid vibration and impact to output head, or it may be damaged.
CAUTION: Make sure the aperture and the cavity of the processing head
is clean;
Keep the protective cap properly, prevent it from contamination; Or the
aperture will be contaminated when capped.