Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C30000XZ
52
5
,
XP1-A5 is connected to 24 V to turn on red light; After checking the optics, connect XP1-
A5 to 0V and turn off the red light;
6
,
XP1-C1 is connected to 24 V, and the main power supply is powered on (you can also
directly press the LASER button, or click the ON button in the main power supply of the
upper computer software);
7
,
Wait for Ready button
;
8
,
XP1-
(
A8-14
)
selects the pre-executed program number, and XP1-A2 sets high level to
start operating the program;
Figure 33 Timing diagram of control signal of programming mode.
7 RS232 and INTERNET Communication Command
7.1 Port Configuration
RS-232 configuration is as follows:
baud rate :9600, data bit :8, stop bit :1, no parity bit and no control flow.
Ethernet port is configured as follows:
Default laser IP address :192.168.0.10
Laser port :10001