RG74T-R Operator · Service · Maintenance
44
Maintenance
Cooling System - Check
Check the cooling level in the radiator.
1. When it is below the sight glass (1) shown above
2. When the coolant level drops due to evaporation, add
50% water-antifreeze mix only up to the full line.
3. Periodically inspect the coolant system for obstructions
and debris. Clean out the cooling system and the engine
compartment as described in the Cummins Engine
Manual.
Radiator
Flush & Refill
• Remove the radiator cap (2)
• Place a container under the radiator drain and loosen
the drain plug (3).
• When the radiator is empty, re-tighten the radiator
drain plug (3).
• When refilling the radiator, see your Cummins Engine
Manual for coolant specifications.
• With the radiator cap removed, start the engine.
• Check the amount of fluid in the radiator (1), adding
coolant as necessary.
• When the coolant level in the radiator remains constant,
replace the cap on the radiator and re-secure the cover
to the top of the engine enclosure.
Air Cleaner
Clean & Change Cartridges
1
DO NOT REMOVE RADIATOR CAP AFTER ENGINE
HAS BEEN OPERATED OR ENGINE IS HOT.
NOTICE
The coolant level should be checked daily.
2
3
4
6
5
Summary of Contents for RG74T-R
Page 23: ...RG74T R Operator Service Maintenance 800 392 2686 23 Safety ...
Page 24: ...RG74T R Operator Service Maintenance 24 Operation 3 5 6 8 1 4 11 2 7 4 9 10 12 13 ...
Page 35: ...RG74T R Operator Service Maintenance 800 392 2686 35 Operation ...
Page 55: ...RG74T R Operator Service Maintenance 800 392 2686 55 Main Wiring Harness 35170 G ...
Page 58: ...RG74T R Operator Service Maintenance 58 Hydraulic Schematic 805039 ...