Copyright © 2000 Rayco - All Rights Reserved
Printed in U.S.A.
41
RAYCO
®
RG 1635A STUMP CUTTER
M
AINTENANCE
I
NTERVALS
Every 125 Service Hours
Battery
- Check
WARNING
A l w a y s w e a r p r o t e c t i v e c l o t h i n g a n d
e y e g l a s s e s w h e n w o r k i n g w i t h b a t t e r y .
F o r f u r t h e r i m p o r t a n t b a t t e r y s a f e t y
information, consult the
Deutz [Engine]
Operation Manual
.
Clean Terminals
1. Remove battery box lid.
2. Remove black negative (-) cable.
3. Clean terminal and clamp of any oxidation
buildup with stiff wire brush. (Stroke brush
away from your body to avoid hazardous
particles.)
4. Apply a light coat of petroleum jelly around
base of terminal.
5. Repeat same procedure for red positive (+)
cable.
6. Replace both cables.
Adjust Electrolyte Level
1. Remove battery box lid.
2. Remove each cap carefully by prying with a
screwdriver.
3. Electrolyte level should be 1/4" to 1/2" above
metal plates (just touching bottom of plastic fill
neck). Add distilled water as needed.
4. Replace both caps.