Wiring external to the appliance must be installed in
accordance with current National Wiring Regulations and
any local regulations which apply. The appliance is
supplied for 220/240 Volt ~ 50Hz and a fuse rating of 5
amps.
The method of connection to the mains supply should
facilitate complete electrical isolation of the appliance, by
the use of a fused double pole switch having a contact
separation of at least 3mm serving only the appliance.
The point of connection to the mains should be readily
accessible and adjacent to the appliance. The installation
should be protected by a 30mA Residual Current Circuit
Breaker (RCCB).
The minimum requirement for the power cable is that it
should be a 3 core PVC sheathed flexible cord (85°C min)
at least 0.75mm
2
(24 x 0.2mm) to the relevant standard.
WARNING: THIS APPLIANCE MUST BE EARTHED
In the event of an electrical fault after installation of the
appliance, preliminary electrical system checks must be
carried out i.e. earth continuity, short circuit, polarity and
resistance to earth.
For wiring instructions see wiring diagram.
NOTE: WHEN WIRING THE INSTALLATION IT MUST
BE REMEMBERED THAT THE PUMP MUST BE ON
WHILE THE BOILER BURNER OPERATES.
The wiring of the pump is dependent on its position
relative to the appliance. Where it is close to the appliance
then it can be wired directly into the terminals on the
control panel, marked PUMP.
Details of the wiring of the appliance and system are
given in figures 6 and 7.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE HAVE MORE THAN ONE POWER
SOURCE. ALL POWER TO THE APPLIANCE MUST GO
THROUGH ONE SINGLE 5 AMP FUSED ISOLATOR
SWITCH.
General
The appliance is floor mounted and the space in which the
appliance is to be fitted must have the following minimum
dimensions:-
Between wall and L.H. side of appliance
300mm
Between wall and R.H. side of appliance
Zero
Above the raised insulated cover handle
60mm
In addition, adequate clearance must be available at the
front of the appliance to enable it to be operated and
serviced.
The appliance is delivered in a fully assembled condition
with the exception of the following items which are
supplied separately packed and require assembly:-
The appliance rear distance bracket
The cooker handrail
Appliance rear distance bracket: If the rear wall is of
combustible material, there must be an air gap of 25mm
between the wall and the rear of the cooker. Fit the rear
distance brackets as shown in Fig. 5. Whenever possible
it is recommended that the skirting board is removed for
the width of the appliance to enable the rear edge of the
appliance top plate to make contact with the vertical wall
and avoid a rear gap. (Combustible wall excepted).
Where the cooker is to stand in a recess or against a wall
which is to be tiled,
IN NO CIRCUMSTANCES SHOULD
THE TILES OVERLAP THE TOP PLATE
.
The handrail brackets are held on the front end of the
cooker top-plate casting. Remove the travel nuts and
replace with the handrail brackets ensuring the fibre
protecting washers are in position. Insert the handrail with
fitted endcaps into the brackets, positioning then correctly,
and tighten the locating bolts (Fig. 5).
ELECTRICAL SUPPLY
6
INSTALLATION OF APPLIANCE
DESN 510454 A
Fig. 5
DESN 511072