16
Servicing or Fault
BURNER RESET
SEE FIG. 18
If a fault occurs on the burner then it automatically shuts
down and the red button on the front plinth will be
illuminated. This can be reset, after 1 minute by depressing
the button. The reset button is located in the lower plinth
panel.
OPERATE BY PRESSING WITH FINGER ONLY
Please wait at least 60 seconds between resetting the
lockout button.
If for example the storage tank has been replenished after
the oil supply ran out, and resetting the lockout button does
not light the burner immediately, it will be necessary to
repeat the sequence.
Continued lockouts indicate a burner or oil supply
malfunction. The fault should be diagnosed and rectified.
In the event of repeated failure, switch off the oil and
electrical supply to the appliance and contact your
installer/service engineer.
FLUE SAFETY DEVICE (IF THE BURNER GOES OUT OR
WILL NOT OPERATE)
For safety purposes a flue safety device is fitted. This will
only operate under adverse flue conditions. If the switch has
operated, it should be pushed in to reset and the pilot re-lit.
If this problem persists contact the local engineer to
determine and rectify the cause. It is important not to re-set
more than once as this may indicate a flue blockage.
OIL LEAK OR FAULT
If an oil leak or fault exists or is suspected the unit must be
isolated from the oil and electrical supply. The appliance
must not be used until the fault has been rectified.
Advice/help should be obtained from the installer/servicing
company.
POWER FAILURE
In the event of a short term power failure the clock display
will disappear and then return on the power supply being re-
instated.
However if the power supply is interrupted for any length of
time the clock display will be lost. Follow procedure ‘
TO
SET TIME
’.
FUEL
Please endeavour to see that when the fuel is being
delivered into the storage tank, that the appliance is left off
during delivery, and preferably for a period of 1 hour
afterwards to allow sediment within the tank to settle.
To avoid break downs through fuel starvation avoid running
out of fuel. Order a supply in ample time
SERVICING
With normal use the cooker will need an annual flueway
clean and burner maintenance.
An additional flue-way clean half-way through the season
may be necessary in some cases - see Servicing
Instructions.
THE EXTERNAL FLUE
The extractor fan should be regarded as a consumable item
and replaced every 2 years.
A HOT APPLIANCE CANNOT BE SERVICED.
The cooker thermostat knob should be turned OFF the night
before the day of the servicing so that the appliance will
have cooled down.
Fig. 18
BURNER RESET
BUTTON
FLUE SAFETY
DEVICE