5.11 INTAKE AND EXHAUST TERMINAL COMPONENTS
Fig.17
IMPORTANT: Please lubricate the
internal part of the seals before
fitting.
5.12 IN-LINE FLUE BEND AND FLUE EXTENSION
Fig.18
49 - In-line Flue Bend
52 - Self-cutting joint securing screw
52 - Self-cutting joint securing screw
56 - Rubber seal Ø 100
59 - Rubber seal Ø 60
63 - Air intake duct extension
64 - Flue exhaust duct extension
34
KEY
50 - Flue adapter
50 - Flue adapter
52 - Self-cutting joint securing screw
52 - Self-cutting joint securing screw
56 - Rubber seal Ø 100
57 - Elbow header
58 - Header gasket
59 - Rubber seal Ø 60
60 - Fumes sample point
61 - STD fl ue exhaust duct
62 - Terminal
65 - Flue manifold rubber seal
66 - Securing screw
67 - Flue temperature sensor
69 - Air sample point
127 - Terminal Rubber wall seal
Fig 16
IN-LINE FLUE BEND
Measure the distance between the flue bends or
the flue/terminal assembly. The measurements
should be taken from the outer edge of the flue
and bend (fig. 18).
5.10
COMPLETING HORIZONTAL FLUE
INSTALLATION.
Ensure the flue system has been checked for
soundness, is stable and secure. Where the
horizontal flue terminal passes through the
external wall,
it is essential that the flue must
be sealed on both in exterior and interior
part of the wall, and securing screws fitted.
The terminal rubber must also be fitted
(fig. 16-17 item 127).