3
Manual No. 016-5034-020 Rev. B
13
Hydraulic System Installation
Install Fittings in the Flow Switch
FIGURE 2.
Fittings Installed in Flow Switch
1.
Remove the existing hydraulic fittings from Ports A1 and B3 of the flow switch (P/N 334-0003-085).
Note:
The existing hydraulic fittings are not used in the SmarTrax system.
2.
Remove the pressure transducer from Port B1.
3.
Remove the plugs from Ports A2 and B2 and install them in Ports A1 and B1.
4.
Install the pressure transducer in Port B3.
5.
Install -8 ORFS (M) to -6 SAE O-ring (M) straight adapter fittings (P/N 333-0012-082) in Ports A2 and B2 of
the flow switch.
Install Fittings in the Hydraulic Float Valve
FIGURE 3.
Fittings Installed in Hydraulic Float Valve
1.
Remove the hydraulic port plugs from the Ports A1, A2, B1 and B2 of the hydraulic float valve (P/N 063-
0131-136).
2.
Install -8 ORFS (M) to -6 SAE O-ring (M) straight adapter fittings (P/N 333-0012-082) in the open ports.
Summary of Contents for SmarTrax John Deere 8X60 Series
Page 1: ...SmarTrax Installation Manual John Deere 8X60 8X70 Series...
Page 4: ...Table of Contents ii John Deere 8X60 8X70 Series SmarTrax Installation Manual...
Page 14: ...Chapter 2 10 John Deere 8X60 8X70 Series SmarTrax Installation Manual...
Page 28: ...Chapter 3 24 John Deere 8X60 8X70 Series SmarTrax Installation Manual Hydraulic Diagram...
Page 36: ...Chapter 4 32 John Deere 8X60 8X70 Series SmarTrax Installation Manual System Diagrams...
Page 37: ...4 Manual No 016 5034 020 Rev B 33 Cab Component Installation...
Page 38: ...Chapter 4 34 John Deere 8X60 8X70 Series SmarTrax Installation Manual...
Page 39: ...4 Manual No 016 5034 020 Rev B 35 Cab Component Installation...
Page 40: ...Chapter 4 36 John Deere 8X60 8X70 Series SmarTrax Installation Manual...
Page 44: ...Index 36 John Deere 8X60 8X70 Series SmarTrax Installation Manual...
Page 47: ......