CHAPTER
5
Manual No. 016-0190-060
17
Chapter 5
Wiring and Electrical
Connections
Connecting the SmarTrax Hydraulic Valve
1.
Place a solenoid gasket (included in the packet with the console cable harness) on the solenoid installed in
port ‘1A’ on the SmarTrax hydraulic valve (P/N 334-0003-066).
2.
Locate the connector labeled ‘LEFT’ on the SmarTrax console cable harness (P/N 115-0171-775).
3.
Insert the connector labeled ‘LEFT’ to the solenoid installed in port ‘1A’ on the SmarTrax hydraulic valve.
4.
Tighten the bolt on the solenoid connector to secure the connection and to help prevent moisture
penetration.
5.
Repeat step 1 through step 4 to connect the ‘RIGHT’ connector to the solenoid on port ‘1B’.
FIGURE 1.
Solenoid Connections on the SmarTrax Valve
CAUTION
Ensure that the power cable is the last cable
connected.
Do not reverse the power leads. Doing so will
cause severe damage to the equipment.
Ensure the leads are connected to the correct
polarity.
Solenoid
Connections
Summary of Contents for SmarTrax Case IH MX 210
Page 1: ...Case IH MX 210 230 255 285 SmarTrax Installation Manual...
Page 4: ...Table of Contents ii CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...
Page 12: ...Chapter 2 8 CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...
Page 31: ...7 Manual No 016 0190 060 27 System Drawings Envizio Pro Viper Pro...
Page 32: ...Chapter 7 28 CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...
Page 33: ...7 Manual No 016 0190 060 29 System Drawings...
Page 34: ...Chapter 7 30 CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...
Page 35: ...7 Manual No 016 0190 060 31 System Drawings Cruizer...
Page 36: ...Chapter 7 32 CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...
Page 38: ...Index 34 CaseIH MX 210 230 255 and 285 SmarTrax Installation Manual...