4
Manual No. 016-0159-845
17
Installation
Fan Sensor
FIGURE 8.
Fan Sensor Assembly
1.
Attach the fan RPM sensor to the fan sensor bracket using a stainless steel bolt, lock washer, and nut.
2.
Mount the fan sensor assembly on the fan sensor mounting tab using a stainless steel bolt, lock washer,
and nut.
FIGURE 9.
Fan Sensor Adjustment
3.
Adjust the air gap between the fan gear and fan sensor to between .040 and .080 inch.