background image

Index

52

SCS 660 & 660M Serial Interface for Granular Applications Installation & Service Manual

Summary of Contents for SCS660M

Page 1: ...SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 2: ...en Industries cannot guarantee the accuracy integrity continuity or availability of the GPS signal from the U S Department of Defense NAVSTAR GPS satellites the OmniSTAR correction service or the WAAS...

Page 3: ...t Calculation 7 New Leader Mark IV Interface Spreader Constant Values 8 Calculate the Meter Cal Value 9 Calculate the Valve Cal Value 9 Calculate the Rate Cal Value 10 Chapter 3 Calibration Card 11 In...

Page 4: ...onsole Programming 32 Programming Additional System Data 33 Vol Tank 33 Time and Date 33 Power Down 33 System Features 34 Data Menu 34 Data Logger On Off 35 Self Test Feature 36 Volume Min Rate Fault...

Page 5: ...Manual No 016 0159 845 iii Testing Flow Meter Encoder Cables 43 Speed Sensor Cables 44 Testing Speed Sensor Extension Cables 44 Troubleshooting 45 Console Issues 45 Rate Control Issues 46 Chapter 8 Re...

Page 6: ...Table of Contents iv SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 7: ...ts for missing or damaged safety labels contact your local Raven dealer When operating the machine after installing the SCS 660 Serial Interface system observe the following safety measures Be alert a...

Page 8: ...hine manufacturer s approved maintenance instructions When installing AutoBoom hydraulics or performing diagnostics maintenance or routine service ensure that precautions are taken to prevent any fore...

Page 9: ...erface for Liquid Applications Installation Service Manual P N 016 0159 841 for information on liquid applications The operator sets the target weight per area to be applied and the SCS 660 automatica...

Page 10: ...Acre km Kilometers kg ha Kilograms per Hectare km h Kilometers per Hour PPK Pounds per 1 000 Square Feet US Volume per Acre mm Millimeters SI Volume per Hectare cm Centimeters TU Volume per 1 000 Squa...

Page 11: ...his value may be adjusted to optimize the system s performance Wheel Drive Speed Sensors Only Important This procedure should be performed only after the entire system installation is complete This pr...

Page 12: ...ted every time the gate opening dimensions are changed Formula Calculation First use a tape measure to measure the following dimensions on the machine Gate height GH in inches cm Gate width GW in inch...

Page 13: ...ecimal in METER CAL 2 Enter a value of 200 in METER CAL 3 Enter 0 in TOTAL VOLUME 4 Run the machine under normal operating conditions collecting a sample large enough to weigh accurately 5 Weigh the s...

Page 14: ...y dividing 1172 by the exact height of the gate opening For your convenience we have calculated the spreader constant values in one inch increments listed below 2020 Box with 0 192 Chain and Belt Over...

Page 15: ...shift feature explained in the Decimal Shift Feature section on page 39 Calculate the Valve Cal Value The Valve Cal figure is used to control the response time of the control valve motor to the change...

Page 16: ...acklash Controls the time of the first correction pulse after a change in correction direction is detected INC to DEC or DEC to INC 1 9 1 Short Pulse 9 Long Pulse Valve Speed Controls the response tim...

Page 17: ...on Located on the next page is a card that may be used to record the machine s calibration values Write the calibration numbers in pencil so that they may be revised if necessary Cut on the dotted lin...

Page 18: ...Chapter 3 12 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 19: ...ine on a level surface 2 Select the radar mounting location on the machine considering the following factors The line of sight from the lens to the ground must not be obstructed by structures or tires...

Page 20: ...Eight Hole Wheel Stud Patterns Optional This section is required only on wheels that do not have pre punched mounting holes If your machine has the pre punched mounting holes proceed to the Mounting t...

Page 21: ...wheel dividing the wheel into four equal parts 4 Measure in one inch from the rim on each end of the lines and mark the wheel at each point 5 Drill a 1 2 hold on each of the four marks Note The distan...

Page 22: ...4 1 6 mm 25 mm Make sure the machine s wheels can be turned to the extremes in each direction without the magnets coming in contact with the switch assembly 5 Tighten the mounting hardware to secure...

Page 23: ...or to the fan sensor bracket using a stainless steel bolt lock washer and nut 2 Mount the fan sensor assembly on the fan sensor mounting tab using a stainless steel bolt lock washer and nut FIGURE 9 F...

Page 24: ...Locations FIGURE 11 Mounted Bin Level Sensor 1 Use the mounting plate as a template to mark the holes in the appropriate bin sensor mounting location 2 Drill and de burr the mounting holes 3 Align the...

Page 25: ...r 3 Install the coupler on the end of the encoder 4 Mount the encoder and coupler on the output shaft of the conveyor 5 Install the provided set screws in the coupler to secure the encoder on the outp...

Page 26: ...iagram 1 Install the control valve with the motor in the upright position in the location appropriate for the machine s configuration Refer to the diagrams above Spinner System Pneumatic System Open H...

Page 27: ...nnect the white wire on the radar power cable to the white wire on the console control cable 4 Turn the POWER ON OFF switch on the console to OFF 5 Route the red wire on the console control cable to t...

Page 28: ...Chapter 4 22 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual FIGURE 14 SCS 660 Console Cabling Diagram...

Page 29: ...4 Manual No 016 0159 845 23 Installation FIGURE 15 SCS 660M Console Cabling Diagram...

Page 30: ...ystem will not be used for an extended period of time for example two weeks be sure to disconnect the SCS 660 battery wires If the wires are not disconnected and the SCS 660 is only turned OFF the sys...

Page 31: ...may be necessary to contact Raven Industries with questions about the SCS 660 system The SCS 660 console has an identification label affixed that contains information useful to the Raven customer sup...

Page 32: ...manual or fully automatic control Manual override control provides the capability of spot application Turns the console power on or off Toggles to variable submenus within a menu except in Data Menu E...

Page 33: ...rol provides the capability of spot application Turns the console power on or off Displays the rate of application calibration and function data Used to scroll through the menu options in Data Menu To...

Page 34: ...CAL Target application rate TIME 24 hour clock military time Button Name Function TOTAL AREA Displays total area applied To zero out this figure press ENTER 0 then ENTER in this menu TOTAL VOLUME Dis...

Page 35: ...he first six steps of this procedure turn the POWER ON OFF switch to the OFF position press CE and hold while turning the POWER ON OFF switch to the ON position to reset the console Refer to the value...

Page 36: ...ed Note If a second rate is not being used enter the same value that was entered for the Rate 1 Cal The initial console programming is now complete and the flashing CAL in the console s display should...

Page 37: ...ld be approximately 5280 1000 If the value is between 5260 5300 990 1010 the speed cal value for the machine is 785 200 If the value is any other value use the following formula to recalculate the spe...

Page 38: ...rs in the display 2 Press ENTER The message CAL SP1 WHEEL DRIVE will appear in the console s display 3 Select the type of sensor being used by pressing the CE button until the desired sensor type appe...

Page 39: ...The VOL TANK variable will have to be updated each time the tank is refilled Time and Date Note The system runs on a 24 hour clock Therefore for any time after 12 59 pm add 12 hours to the time For ex...

Page 40: ...r is On the alarm sounds and the display flashes SHAFT 2 if the right shaft should be rotating but is not BIN LEVEL FAULT OFF Turns the bin level fault detector on and off When the fault detector is t...

Page 41: ...NU use the arrow keys to advance to HIGH PWM OFFSET 253 2 Move the product switch to MAN and the boom switches and master switch to ON 3 Hold the INC DEC switch to increase the RPMs If the motor excee...

Page 42: ...s R126C D1 total_area field_area CR LF R126C D2 total_volume field_volume CR LF R126C D3 tank_volume distance CR LF Actual Rate R126C AR actual_rate CR LF Time Date R126C TD hr min month day year fiel...

Page 43: ...nds The alarm may be turned off thru the DATA MENU Low Tank Fault The SCS 660 console alarm will sound if the volume in the tank drops below the value entered into the console The alarm will intermitt...

Page 44: ...ations to build up pressure when turning the master switch on For best results approach the headlands at consistent speeds while turning all boom sections off Zero Speed Shut Off The Zero Speed Shut O...

Page 45: ...sition 2 Press CE and hold while turning the POWER ON OFF switch to the ON position Decimal Shift Feature Important When entering data for Rate 1 Cal and Rate 2 Cal remember that 2 GPA 20 lit ha is en...

Page 46: ...Decimal Place 1 Press the METER CAL button 2 Press the SELF TEST button 3 Enter the flow meter calibration value stamped on the identification tag 4 Press ENTER Unshift the Decimal Place 1 Press the...

Page 47: ...h boom operates by toggling the boom switches between ON and OFF 10 Hold the INC DEC switch in the INC position for approximately 12 seconds noting the maximum rate value in the display 11 Hold the IN...

Page 48: ...l performing correctly refer to Chapter 7 Preventative Maintenance and Troubleshooting for possible causes and corrective action 6 At the end of each row switch the boom switches to OFF to shut off th...

Page 49: ...1 Disconnect the cable from the flow sensor FIGURE 1 Flow Sensor Connector Cable Connection Note If a 5 VDC voltage reading is not present disconnect the speed sensor cable If the flow reading is rest...

Page 50: ...If the speed reading is restored refer to the Testing Flow Meter Encoder Cables section on page 43 to test the flow meter cables If the speed system is a radar type system the voltage between the 10 o...

Page 51: ...the field The console display message flashes CAL whenever the vehicle s engine is started Check the battery voltage and connections The console display message flashes CAL whenever the Master switch...

Page 52: ...CAL figure after testing is complete Issue Corrective Action The RATE displays as 0000 1 Verify that the SPEED is registering correctly If the speed is zero refer to the The SPEED is inaccurate or uns...

Page 53: ...the valve connector a Turn the Master switch ON b Switch the RATE 1 RATE 2 MAN switch to MAN c Turn the POWER switch ON d Manually operate the INC DEC switch to verify voltage 4 Verify that the valve...

Page 54: ...Chapter 7 48 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 55: ...CHAPTER 8 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual 49 Chapter8Replacement Parts...

Page 56: ...Chapter 8 50 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 57: ...nformation Electrical 2 Hydraulics 2 Initial System Setup and Testing Initial Setup 41 Initial System Field Test 41 Installation Console and Cabling 21 Control Valve 20 Alternate Bypass Line Plumbing...

Page 58: ...Index 52 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Page 59: ...Coverage Period How Can I Get Service What Will Raven Industries Do What is not Covered by this Warranty Bring the defective part and proof of purchase to your Raven Dealer If your Dealer agrees with...

Page 60: ...reserved under copyright laws Raven Industries Toll Free U S and Canada 800 243 5435 Applied Technology Division or Outside the U S 1 605 575 0722 P O Box 5107 Fax 605 331 0426 Sioux Falls SD 57117 5...

Reviews: