19
4.
VOLUME/MINUTE RATE FAULT
Depress
until DATA display flashes. A low limit flow rate may now be entered.
If the actual volume per minute falls below this limit, the Control Valve stops
closing, an alarm sounds, and the display flashes "-LL-". The low limit value
should be determined with all booms ON. This value is automatically proportional
to the percentage of booms that are ON. (i.e. If the entered low limit is 4 and
half the total boom length is shut off, the Console automatically reduces the low
limit to 2).
NOTE: Go to DATA MENU to silence alarm.
5.
VOLUME/AREA RATE ALARM
Console alarm sounds if the application rate is 30% or more away from the
target application rate for more than 5 seconds.
NOTE: Go to DATA MENU to silence alarm.
7.
AUTOMATIC RATE +/-
This feature sets the increment at which flow is increased or decreased
in RATE 1 or RATE 2 operation. Enter rate change value by depressing key
labelled
until DATA display flashes. To enter a value depress
,
then the increment value, and
.
EXAMPLE:
If rate is to change by "1.0":
Enter a value of 1.0 for RATE +/-. When in RATE 1 or RATE 2, each time
the INC/DEC switch is positioned to INC the RATE CAL for that rate will
increase by "1.0". Likewise, when positioned to DEC the RATE CAL will
decrease by "1.0".
6.
LOW TANK FAULT
This feature will sound the alarm when the volume in the tank drops below
an entered value. The alarm will intermittently beep every 15 seconds and
the RATE display will flash "LEVL". The alarm will stop when a value equal
to or greater than the LOW TANK ALARM is entered into VOL/TANK or the booms
are turned OFF. Entering "0" into LOW TANK ALARM disables it.
To select LOW TANK ALARM depress
until DATA display flashes. To enter
value depress
,then LOW TANK ALARM value, and
.
NOTE: Go to DATA MENU to silence alarm.