15
5)
Display C-Sd (Standard Valve), C-F (Fast Valve), or C-FC (Fast Close Valve).
a)
Depressing momentarily
steps the DATA display from C-Sd to C-F.
b)
Depressing momentarily
steps the DATA display from C-F to C-FC.
c)
Depressing momentarily
steps the DATA display from C-FC to C-Sd.
6)
Selecting C-Sd, C-F, or C-FC.
a)
To select C-Sd, C-F, or C-FC, step
until desired code is displayed.
b)
Momentarily depress
, the DATA display will now display "0".
7)
Definition of Boom Calibration keys.
Depressing this key displays selected boom number in DATA display.
EXAMPLE: Boom 1 will be displayed as b-01.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE: b-01 will change to b-02.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE: b-02 will change to b-01.
Enter Boom Data:
a)
Select boom b-01.
b)
Use boom width as calculated under "CALCULATING BOOM CAL".
c)
If a boom is not needed, enter a "0" for the length.
8)
Enter SPEED CAL as calculated under "CALCULATING SPEED CAL" in key labelled
9)
Enter METER CAL calibration number in key labelled
.
10)
Enter VALVE CAL calibration number in key labelled
.
11)
Enter RATE 1 CAL (lbs/acre) [Kg/ha] target application rate in key labelled
.
12)
Enter RATE 2 CAL (lbs/acre) [Kg/ha] target application rate in key labelled
(If you do not use a second rate, enter the same rate as RATE 1 CAL).