CHAPTER 9
84
Raven SC1™/TC1™ Calibration & Operation Manual for Towed Implements
SYSTEM HEALTH TESTS
FIGURE 5. Test Selection Page
System health tests are performed to diagnose and correct machine and SC1/TC1 calibration issues. The following
system health tests can be performed via the SC1/TC1 system:
• Step Response Test
• Machine Test
STEP RESPONSE TEST
The Step Response Test is used to determine the responsiveness of the implement steering system.
FIGURE 6. Step Response Test Page
1. Drive forward 1 - 4 mph with the engine RPM set at 3/4 throttle.
WARNING
The machine will steer automatically while system
heath tests are being performed. Be sure the area
around the vehicle is clear of people and
equipment before engaging the SC1/TC1 system.