Pagina 14/20
I April 2017 I 2.0
SmartGrid
3.2.2. Grid information
Press on the second tab (
i
-icon) to look at the
diagnosis information (
The available information about grid and
gridpoints are shown in this menu.
ROW:
The row number (row 1 = working line 1
= line between the two red dotted lines).
The value between the brackets next to
the rownumber is the distance to working
line 1.
PLANT:
Plant number in the row (plant 1 is the
plant between the red dotted lines right
angle on the driving direction) the value
between the brackets next to the plant
number is the distance from the closest
plantnumber to the A-point of the AB line.
FAILURES:
Number of failures since the start of the
count.
FAILURES %:
Percentage missed grid points relative to
the total number of grid points.
DISTANCE TO TRC:
Distance to the next grid point (TRC=
Target Raster Coordinate). Blue mark on
the screen
DISTANCE TO NRC:
Distance to the closest grid point (NRC=
Nearest Raster Coordinate) Red mark on
the screen.
ERROR:
Error relative to the last grid point.
Figuur 11 Grid diagnostic information