4
System Setup: System Settings Tab
31
SYSTEM SETUP
MINIMUM PRESSURE
The minimum pressure feature requires a pressure transducer to monitor product pressure during application and
sets the lowest allowable pressure to which the product system will control during applications.
NOTE:
Default minimum is 20 PSI [137.9 kPa].
The minimum pressure feature may result in higher than desired application rates. If the minimum
pressure feature will be used during field applications, be sure to enter a value that will not interfere
with normal target rates.
If the application system reaches the minimum pressure setting, the UT will display an alert and the system will
maintain the flow rate to keep the monitored pressure consistent. This feature may be used to help maintain
boom pressure and the nozzle spray pattern if product application rates and equipment speeds are close to the
low end of the suggested ranges.
NOTE:
Enable the minimum pressure alarm to enable an audible alarm when the minimum pressure
threshold is reached. The minimum pressure alarm is a global alarm option.
MAXIMUM PRESSURE
The maximum pressure feature requires a pressure transducer to monitor product pressure during application and
sets the highest allowable pressure to which the product system will control during applications.
NOTE:
The maximum pressure feature may result in lower than desired application rates. If the maximum
pressure feature will be used during field applications, be sure to enter a value that will not interfere
with normal target rates.
If the application system reaches the maximum pressure setting, the UT will display an alert and the system will
maintain the flow rate to keep the monitored pressure consistent at the maximum pressure.
NOTE:
The maximum pressure for
Hawkeye® 2 NCVs is 120 PSI [827.4 kPa].
BOOM AND SPARGE PRESSURE
NOTE:
A boom pressure transducer is required for system operation.
If detected during the calibration wizard, the system will allow the user to select the pressure
transducer range for the boom and sparge transducer.
NCV2 READINGS
NOTE:
NCV2 readings are not available in the Bypass NCV2 control mode.
To adjust pressure settings:
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
RCM - Sprayer Menu
Tools Menu
System
Settings
UT Menu
NCV2
Readings
Summary of Contents for RCM-Sprayer Hawkeye 2
Page 6: ...TABLE OF CONTENTS iv RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 10: ...CHAPTER 1 viii RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 20: ...CHAPTER 2 10 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 28: ...CHAPTER 3 18 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 52: ...CHAPTER 5 42 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 60: ...CHAPTER 6 50 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 66: ...CHAPTER 8 56 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 90: ...APPENDIX A 80 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 94: ...APPENDIX B 84 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 108: ...APPENDIX D 98 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...
Page 120: ...APPENDIX F 110 RCM Sprayer and Hawkeye 2 Calibration and Operation Manual ...