Chapter 4
22
Case IH SPX 3230, 3320, and 3330 SmarTrax™ Installation Manual
FIGURE 10.
Valve Harness Connected to Flow Switch
3.
Plug the PS1 and PS2 connectors from the valve cable into the pressure transducers installed on the flow
switch (P/N 334-0003-085).
Note:
These connections can be plugged into either transducer.
4.
Plug the VALVE connector from the valve cable into the open port at the end of the SmarTrax valve (P/N
334-0003-088).
Install the Foot Switch
FIGURE 11.
Foot Switch Installed
1.
Select a suitable location for the foot switch (P/N 063-0172-470) to be installed.
Note:
The foot switch should be installed in a location where the operator has easy access to it and is
able to fully press the pedal.
2.
Using the holes in the foot switch as a template, drill holes in the floor of the cab.
3.
Secure the foot switch to the floor by installing the supplied screws in each of the mounting holes.
4.
Locate the ENABLE connector on the node harness and connect it to the foot switch cable connector
behind the operator’s seat.