![Ravelli Sara Owners And Installation Manual Download Page 12](http://html2.mh-extra.com/html/ravelli/sara/sara_owners-and-installation-manual_3836960012.webp)
10
Page 8
To set the desired temperature press button [4] then use
button [1] & [2] to achieve the desired value. When the set
temperature on the display is reached, MODULATION
WORK will appear on the screen and the fi re will drop to
its lowest power setting.
6.4
Menu Three - Select Language
(Setting the Language)
Some fi res may be in their default Italian language, if so
proceed with Instruction Set ‘A’.
If not, please use Instruction Set ‘B’.
A. Setting fi re from Italian language to your desired
language. (English, German, French, Danish)
1. Press button [7] (Menu 01 “Set Orologio” will appear)
2. Press button [1] twice until you see (Menu 03 “Scegli
Lingua”)
3. Press [7] to enter into this menu (“Italiano Lingua”
should appear)
4. Press [1] or [2] until you see “English Lingua” or
select your desired language.
5. Press [3] twice to return to the main screen.
B. Setting fi re from English language to your desired
language. (Italian, German, French, Danish)
1. Press button [7] (Menu 01 “Set Clock” will appear)
2. Press button [1] twice until you see (Menu 03 “Select
Language”)
3. Press [7] to enter this menu (“English Lingua” will
appear)
4. Press [1] or [2] to change to your desired language.
5. Press [3] twice to return to the main screen.
6.5
Menu Four - View Settings
In this menu you can check the values of the parameters
set in the control unit. This menu is used when a Service
Technician has to understand the parameters set in
the machine, to fi nd any modifi cations to improve the
functioning of the stove.
6.6
Menu Five - Stove State (Fire Status)
In this menu, you can check the correct functioning of
some of the key components of the pellet fi re.
To enter this menu either
1. Press Button [7] (Menu 01 “Set Clock” will appear)
2. Then press and hold [6] for 3 seconds
Or
1. Press [7] CLOCK SETTING MENU will appear
2. Press [1] four times “fi re State” menu, enter using
[7].
This menu is for use by a service technician for
commissioning and diagnostics, and for the customer
when loading pellets into the auger when the fi re has
been completely run out of fuel.
6.6.1 Loading the Screw (Auger)
Insert Models - Loading the Auger should only be
carried out in OFF mode
When the stove is new or the fi re has run out of fuel, the
auger will be empty. In this case it may be necessary to
‘load’ the auger so the fi re will start.
To load the screw/auger, proceed as follows:
1. Press Button [7] (Menu 01 “Set Clock” will appear),
The auger is activated
2000
150°
COCLEA
1
ST
ATE
The auger is idle
2000
150°
ST
ATE
COCLEA
0
2000
130°C
SCREW 0
STATE 1
Exhaust Fan RPM
Exhaust Temperature
Auger Status
1 = ON 0 = OFF
Stove Status
Note: DO NOT leave the remote down the side
of the sofa, on a window ledge or in a cold
draft, in another room, or in the fl ow of hot
air coming off the fi re. These will give false
readings and the fi re will not control the room
temperature correctly.