background image

Use and maintenance manual Magnus

Pag.17 

Rev.1 21/04/2021

Measurements

Unit of 

measurement

Magnus

Height  

mm 

1351

Width

mm 

1035

Depth

mm 

663

Weight

kg

115

Technical diagram 

Magnus

 1000 

 470 

 505 

 1035 

 880 

 1354 

PORTA REVERSIBILE DX E SX 

 1035 

Ø80 CANALIZZAZIONE

Ø80 CANALIZZAZIONE

Ø80 CANALIZZAZIONE

 391,5 

+  

30 0

 

 505 

 48,55 

 62 

 457 

 668 

KIT RUOTE PER MOVIMENTAZIONE 

DA SMONTARE PER FISSAGGIO 

 226 

CARICO PELLET

REVERSIBILE DX O SX  

USCITA FUMI Ø100 

POSIZIONE REGOLABILE A 180° 

COMPATTATORE CENERE

REVERSIBILE

 767 

 148,5 

 160 

  50 ENTRATA ARIA 

 316 

 310 

VALVOLA ANTISCOPPIO

E ISPEZIONE 

MISURE CON CORNICE PROFONDA

CODICE K0069AZ00

Via Kupfer,31 25036 Palazzolo S/O 

- BRESCIA - ITALY 

MONOBLOCCO MAGNUS

CODICE DISEGNO / REV

AICO S.p.a.

TOLLERANZE GENERALI SECONDO LA CLASSE UNI EN 22768-mK

 

GENERAL TOLERANCES AS PER UNI EN 22768-mK

STATO

FORMATO

TUTTE LE QUOTE MANCANTI SONO DA 

RICAVARE DAL MODELLO 3D

 ALL THE MISSING MEASUREMENTS CAN 

BE FOUND IN THE 3D MODEL

SCALA

DISEGNATO

MASSA

CONTROLLATO

DATA

GRUPPO DI APPARTENENZA

TIPOLOGIA

FOGLIO

1:15

A3

M0001JR00

Assieme Assemblato

-

V.Bertanza

Proprietà della Società 

AICO S.p.A.

 Senza autorizzazione scritta della stessa, il presente 

disegno non potrà essere utilizzato per la costruzione dell’oggetto rappresentato né venire 
comunicato a terzi o riprodotto. La Società proprietaria tutela i propri diritti a rigore di legge.                                                                                         
All proprietary rights reserved by 

AICO S.p.A.

 This drawing shall not be reproduced or in any 

way utilized for the manufacture of the component of unit herein illustrated and must not be 
released to other parties without written consent. Any infringement will be legally pursued.

227.721 Kg

DENOMINAZIONE

1 / 3 

Summary of Contents for Magnus

Page 1: ...USE AND MAINTENANCE MANUAL Magnus...

Page 2: ......

Page 3: ...saanwijzing Beachten Sie die Warnungen und Hinweise betreffend die Installation und regelm ige Wartung in der Bedienungsanleitung Respete las advertencias y las indicaciones de instalaci n y mantenimi...

Page 4: ...tandard The notified laboratory IMQ NB 0051 performed the determination of the product type on the basis of type testing under system 3 and issued test report CS20 0058801 01 8 Declared performances H...

Page 5: ...is Marchio Trademark Marque Ravelli Modello Model Mod le Magnus L oggetto della dichiarazione di cui sopra conforme alla pertinente normativa di armonizzazione dell Unione The object of the declaratio...

Page 6: ...CS 16 Technical diagram Magnus 17 Main parts 18 Description of operation 18 Automatic cleaning system 19 Recharge the fuel 19 User training 19 Safety devices 20 SHIPPING AND INSTALLATION 21 Safety war...

Page 7: ...4 OPERATING PHASES OF THE APPLIANCE 44 Sequence of ignition phases 44 Modulation 44 Description of menu functions 44 Setting 47 Double ducting 49 Stove phase general layout 53 INSTALLATION QUICK GUIDE...

Page 8: ...do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove For further informatio...

Page 9: ...t nominal power part Efficiency at reduced power pnom Minimum draught at nominal power T Flue gas temperature at nominal power 230 V 50 Hz Alimentation Distance to combustible materials dS L Left side...

Page 10: ...the gaskets the paint job the stainless steel or cast iron combustion grille the resistance the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the p...

Page 11: ...erefore if any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical Documentation Office Symbols used in the manual symbol definition This sym...

Page 12: ...e Only use original spare parts Any tampering and or replacementsthathavenotbeenauthorisedbyRavellicanpose a danger to the user s safety In the event of particularly adverse weather conditions the saf...

Page 13: ...he contract and herein the operating manual procedures are followed routine maintenance is carried out according to the times and methods set forth extraordinary maintenance is promptly carried out wh...

Page 14: ...o a regulation chimney provide a suitable system for the supply of combustion air air intake or intake duct for watertight stoves always perform maintenance with the stove off and cold perform cleanin...

Page 15: ...nce Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225 2 2014 standard or certified DIN PLUS more restrictive than the A1 class or ONORM M 7135 Pellet may be light...

Page 16: ...flow g s 7 11 3 Minimum draft Pa mbar 10 0 1 Electrical connection Hz V 230 50 Electrical power consumption max W 650 Electrical power consumption reduced nominal W 72 121 Stand by electrical consumpt...

Page 17: ...ERALI SECONDO LA CLASSE UNI EN 22768 mK GENERAL TOLERANCES AS PER UNI EN 22768 mK STATO FORMATO TUTTE LE QUOTE MANCANTI SONO DA RICAVARE DAL MODELLO 3D ALL THE MISSING MEASUREMENTS CAN BE FOUND IN THE...

Page 18: ...ic control unit there is also that of being able to program the stove s start up and shutdown by setting the weekly chronothermostat All this can be done comfortably from the sofa using the handheld r...

Page 19: ...es It is not recommended to empty the pellet bag directly into the hopper to avoid depositing wood sawdust on the bottom of the hopper To load the pellets inside the hopper proceed as described below...

Page 20: ...rcuit and all the safety systems required by the standards It should be noted that the stove s operating program has been designed to stop stove operation in the event of malfunctions Anomalies Descri...

Page 21: ...lity has a priority over any other assembly or installation operation Local administrative regulations and particular requirements of the authorities pertaining to the installation of combustion appli...

Page 22: ...ollowing regulations it must observe product standard EN 1856 1 it must be made of materials that are suitable to guarantee resistance against normal mechanical chemical and thermal stress and be corr...

Page 23: ...the presence of other combustion appliances or VMC system it is necessary to check the appliance for correct operation The stove must be placed inside living quarters It must never be installed outdoo...

Page 24: ...externally there is another one installed so that the outside section can be inspected It is prohibited to install two 90 bend since the ashes would quickly obstruct smoke passage causing draught pro...

Page 25: ...ment since the ashes would quickly obstruct smoke passage causing draught problems in the stove See Fig 2 INTERNAL CHIMNEY Fig 5 Protection from rain Covering sheet Air tight steel sheet metal T fitti...

Page 26: ...Use and maintenance manual Magnus Pag 26 Rev 1 21 04 2021 Removing of the fixing brackets 1 2 3 x1 x2...

Page 27: ...Use and maintenance manual Magnus Pag 27 Rev 1 21 04 2021 Assembly of the wheels x1 x1 1 2...

Page 28: ...Use and maintenance manual Magnus Pag 28 Rev 1 21 04 2021 Assembly of the baffle 1 2 3 4...

Page 29: ...heet of the insulation product that you will use always respecting local national and European regulations Keep any flammable product such as wooden furniture curtains carpets flammable liquids etc aw...

Page 30: ...E IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO REVISIONE TITOLO N DISEGNO SCALA 1 10 FOGLIO 1 DI 1 A0 P...

Page 31: ...01JR00 A B C D E F G H J K L M N P R T 2 4 2 4 2 3 2 3 2 2 2 2 2 1 2 1 2 0 2 0 1 9 1 9 1 8 1 8 1 7 1 7 1 6 1 6 1 5 1 5 1 4 1 4 1 3 1 3 1 2 1 2 1 1 1 1 1 0 1 0 x4 7 A B C D E F G H J K L M N P R T 18 1...

Page 32: ...O T E I N M I L L I M E T R I F I N I T U R A S U P E R F I C I E T O L L E R A N Z E L I N E A R E A N G O L A R E F I N I T U R A I N T E R R U Z I O N E B O R D I N E T T I N O M E F I R M A D A T...

Page 33: ...and maintenance manual Magnus Pag 33 Rev 1 21 04 2021 16 15 14 13 12 11 Pellet hopper cover x2 x12 x12 x2 1 2 A B C D E F G H J K 2 4 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 x4...

Page 34: ...9 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 DISEG VERIF APPR FABB Qual SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANG...

Page 35: ...8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 D I S E G V E R I F A P P R F A B B Q u a l S E N O N S P E C I F I C A T O Q U O T E I N M I L L I M E T R I F I N I T U R A S U P E R F I C I E T O L L E R A N Z E L...

Page 36: ...ating are different and it is therefore necessary to consult the dedicated brochure Air vents The cladding must be equipped with appropriate air intakes for internal ventilation The air intakes must b...

Page 37: ...nly be connected after the installation and assembly has been completed of the applian ce and must remain accessible after installation To make the electrical connection proceed as described below Fir...

Page 38: ...e fan blades installing the necessary safety measures e g duct grille or pipe longer than 620 mm The duct withdraws much air from the room where the stove is installed releasing it in another room to...

Page 39: ...4 M5 M6 Fase bianco verde rosso nero blu Connessione SONDA o T EXT Rear LEFT Connessione SONDA o T EXT Rear RIGHT T1 T2 M1 M7 M2 LEGEND Safeties T1 Thermal reset T2 Pressure switch Motors M1 Auger gea...

Page 40: ...menu Select the desired language with the scroll buttons and confirm your selection with the confirmation button In order to operate correctly the handheld set should be interfaced with the electroni...

Page 41: ...ttery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the handheld set and observe the poles Install the battery pro...

Page 42: ...UST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Moreover if you p...

Page 43: ...DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NOT POWERED...

Page 44: ...t therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to access the...

Page 45: ...ure If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRONO CHRONO EN...

Page 46: ...RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance should reac...

Page 47: ...W VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the thermostat is in...

Page 48: ...m of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window and the room tempera...

Page 49: ...selection screen Ventilation manual mode When manual management is active the power of the ducting can be changed Press the Access to menu key to access the MENU screen Press the confirm key to access...

Page 50: ...mperature automatic mode When automatic management is active the power of the stove and the speed of the fans are automatically managed so that the desi red temperatures are reached and maintained in...

Page 51: ...desired temperature in the room rooms heated by the ducting the data is saved without further confirmation To go back to the CANALIZED menu press the back key Use the confirm button to go to the enabl...

Page 52: ...in manual mode 3 Left ducting temperature set not considered in manual mode 4 Temperature read by the probe placed in the rooms heated by the right ducting 5 Distribution of the ducting A Auto M manu...

Page 53: ...et is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTART The HOT r...

Page 54: ...ct the Support Service AL 04 FAN BROKEN Fume exhaust encoder is not working or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service The fume extr...

Page 55: ...er the gear motor Check the mains voltage AL 15 AUGER TRIAC An internal part of the electronic board that controls the pellet auger is faulty Check the flue is free and clean Possible voltage drops or...

Page 56: ...6 Rev 1 21 04 2021 EXTERNAL POWER SUPPLY WITH MICRO USB CONNECTOR WIFI MODULE BOARD WITH CONNECTORS FOR EXTERNAL POWER SUPPLY CONNECTION Wifi kit Wifi external power supply kit if applicable MOTHERBOA...

Page 57: ...one tablet entrare nel menu Android Impostazioni Connessioni Wi Fi iOS Impostazioni Wi Fi Selezionare la rete WINET XXXXXXXX ed inserire la chiave WPA indicata nell etichetta del dispositivo wi fi fac...

Page 58: ...ame e g KTR AIR and then click Yes The screen offers a list of firmware once you have identified your model click on Select Yes Close the App and go to step 6 to register the account 4 CONNECTION TO T...

Page 59: ...here you can register the WiFi device WiFi device registration When you click the link in the confirmation E mail the window to register the new device will open click Register your wifi device now ST...

Page 60: ...er and give the module a name e g living room stove STEP 3 complete with your information click Next and then Complete registration STEP 2 enter the product serial number and give the module a name li...

Page 61: ...drawer Glass Combustion chamber Pellet tank Extraction duct In the first periods of use carry out cleaning operations frequently to understand the right frequency of intervention which varies accordin...

Page 62: ...ace a worn component before it is completely broken to prevent any damage caused by sudden component breakage PARTS FREQUENCY 1 SEASON Deep combustion chamber cleaning Door gasket Chimney Smoke condui...

Page 63: ...ABB Qual SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO REVISIONE TITOLO N DISEG...

Page 64: ...ETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA NOME FIRMA DATA MA PES 7 A B C D E F G H J K L M N P 24 23 22 21 20 19 18 17 16 15 14 13 12 x12 A A B B C C D D E E F F G G H H J J K K L...

Page 65: ...place the electronic board contact the Technical Assistance Service AL 15 The flame does not ignite Check that the igniter warms up Check and if necessary replace the igniter AL 05 Air inlet duct bloc...

Page 66: ...ke duct AL 08 The door is not closed perfectly or the gasket are worn Close the door and have the gaskets replaced with original ones AL 05 AL 06 The stove stops automatically Alarm presence Check the...

Page 67: ...ot work Remote control battery low Replace battery or connection to the stove via cable Faulty remote control Replace remote control The stove always works at maximum power Temperature not set correct...

Page 68: ...om is clear of any obstructions and that there are no other combustion appliances or extraction hoods that create a vacuum in the room Difficult lighting closely follow the directions in the dedicated...

Page 69: ...r s parer cet appareil et ou les piles ou les accumulateurs des autres types de d chets et de le confier au service municipal de collecte On peut demander au distributeur de pr lever le d chet d appar...

Page 70: ...r at forebygge ventuelle skader for milj et eller sundheden bedes brugeren om at behandle dette udstyr og eller de medf lgende batterier eller akkumulatorerne separat fra andre affaldstyper og at leve...

Page 71: ......

Page 72: ...f free to make any variations to the features of its products without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del commercio 12...

Reviews: