![background image](http://html1.mh-extra.com/html/ravelli/francesca/francesca_user-and-maintenance-manual_3943766023.webp)
User and maintenance manual for stoves with RDS technology
Pag.23
01/02/2016
The three pictures which follow show the menu with all its icons for the advanced functionalities
The use of the display in advanced mode provides the view of four main menus:
-USER MENU
-DEFAULT SETTINGS (protected by a password)
-BASIC PARAMETERS (protected by a password)
-RDS SETTINGS (protected by a password)
To enter in the USER MENU press two times key OK. The submenus of the USER MENU (the only one accessible for the end user) are
the following:
-Menu STOVE STATUS
-Menu SET ROOM TEMPER ROOM
-Menu SET POWER
-Menu SET CLOCK
-Menu TIMER
-Menu LANGUAGE
-Menu COMFORT CLIMA
-SILENCE
-Mode SELF CONTROL SYSTEM
-Menu VIEW SETTINGS
-Menu VIEW WORKING HOURS
-Menu SET DRAUGHT/PELLET
In this menu you can check the correct functioning of the most important components of the pellet stove, and some values which distinguish
its correct functioning.
To enter in this menu press 3 times the key OK from main screen.
This menu is used both by theautorized technician to understand the reason of the malfunctioning of the stove and by the end user as well
priming he auger.
7.2.1 Menu “STOVE STATUS”
7.2.2. menu “SET ROOM TEMPERATURE”
To enter in the USER MENU press two times key OK.
To enter in the menu “SET ROOM TEMPERATURE” press once key 2 and confirm with OK.
TO MODIFY THE SETTING PLEASE REFERENCE TO PARAGRAPH 7.1.2.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
Speed inlet flow
Screw status
Rpm smoke fan
Smokes temperature
STOVE STATUS
Smokes
Screw status
HOT
Real set flow
COLD
Smokes
Screw status
REAL SET 3,00 m/s
T.DEB 25 °C
50 °C