User and maintenance manual for stoves with RDS technology
Pag.10
01/02/2016
4. Safety devices
The stove is fitted with sophisticated safety systems so that, in the case of breakage of one of the individual parts or defects in the flue,
no damage will be caused to the stove and the room in which it is installed. In any case, when a problem arises, the pellets stop falling
immediately and the “
switch off
” phase is activated.
The corresponding alarm will be shown on the display. The details can be seen in chapter 9 ”DESCRIPTION OF ALARMS”.
5. TECHNICAL FEATURES
Unit of
measurement
Francesca
2015
RV 80
Ceramica
Monica
2015
RV 100
Classic
Roma
SPILLO
RV 100
Height
Inch
37.67
39
39.3
44.1
31.5
30.30
42.5
Width
Inch
17.32
20.20
20.27
21.7
43.4
28
20.87
Depth
Inch
18.46
19.1
18.58
21.9
29.5
25.6
21.25
Weight
Lbs
200
270
264
320
550
451
264-242
Diameter of smoke
exit tube
Inch
3.14
3.14
3.14
3.14
3.14
3.14
3.14
Min-max. hourly
consumption of pellets
Lbs/h
1.1 - 3.5
1.1 - 3.5
1.1 - 3.5
1.5 - 5.1
1.6-5
1.8-6.6
1.1-5.0
Supply
V - Hz
120 - 60
120 - 60
120 - 60
120 - 60
120-60
120-60
120-60
Hopper capacity
Lbs
35
35
35
50
50
44
44
Efficiency *
%
77.9
77.9
77.9
80.2
75.5
85
84
Smoke temperature
min - max
°F
176 - 302
176 - 302
176 - 302
200 - 415
240-410
158-195
217-408
The data shown above are indicative and not binding. Ravelli reserves the right to make any
modifications for the purpose of improving the performances of the product.
6. Positioning, assembly and installation
6.1 Minimum distance from combustible material
B
R
L
A
Unit of measure-
ment
Francesca
2015
RV 80
Ceramica
Monica
2015
RV 100
Classic
Spillo
RV 100
R =right side
Inch/mm
4 / 101,6
4 / 101,6
4 / 101,6
4 / 101,6
7,87 / 200
11,81 / 300
L = left side
Inch/mm
4 / 101,6
4 / 101,6
4 / 101,6
4 / 101,6
7,87 / 200
11,81 / 300
B = rear side
Inch/mm
2 / 50,8
2 / 50,8
2 / 50,8
4 / 101,6
7,87 / 200
7,87 / 200
A = front side
Inch/mm
39,37 /
1000
39,37 / 1000 39,37 / 1000 39,37 / 1000
39,37 / 1000
39,37 / 1000
D = FRONT floor
protection
Inch/mm
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
E = SIDE floor
protection
Inch/mm
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
6 / 152,4
F = Ceiling
Inch/mm
57 / 1450
57 / 1450
57 / 1450
52 / 1321
--
--
E
D
E
N.B. The floor protection must extrend under the chymney connector and 2 inches (50.8mm) beyond each side
NOTE:
Install vent at clearances specified by the
vent manufactures.
*overll heating efficency is determined using higher heating value of the fuel.