background image

Use and maintenance manual Flexi 7 - Flexi 9

Pag.36 

Rev.0  01/03/2023

EN

Failed ignition 

If the system does not detect the ignition of the flame within the preset time, operation will be blocked with the “No ignition” alarm.

Before relighting the stove, check that there are pellets in the hopper, that the door and ash drawer compartment are closed, that there 

are no obstructions to the combustion air inlet system and above all that, in models without self-cleaning brazier, the brazier is empty, 

clean and correctly positioned. If the problem persists, it could be due to a technical problem (ignition plug, adjustments, etc ...), so 

please contact a Ravelli CAT.

 

The accumulation of unburned pellets in the brazier after a failed ignition must be removed before proceeding with a new 

ignition.

 

The brazier could be very hot: danger of burns!

 

Never empty the brazier inside the hopper.

Setting operating temperature and power: 

Set the two values following the indications given in the chapter “Description of the display” 

OPERATING PHASES OF THE APPLIANCE

Sequence of ignition phases        

IGNITION - initial pellet loading phase;

FLAME LIGHT - flame stabilization phase and reduction of combustibl

e inside the brazier;

WORK - operation phase described in the dedicated chapter;

Modulation

During the work phase, the appliance should reach the room temperature set; when this condition is met, the stove switches to MODULATION 

mode in which fuel consumption is minimum.

 

📌

If you wish to detect the ambient temperature by means of an external thermostat (optional), this must be connected to 

the appropriate connector on the rear side of the stove; and you will have to activate the reading in “SETTINGS - ENABLE 

THERMOSTAT.” On display appears the writing TON / TOFF based on thermostat request.

 

Connect an external thermostat with a simple dry contact, therefore, not powered, moreover, we recommend you use a 

thermostat with a minimum offset of 3°C if you ntend to use the comfort clima function.

Description of menu functions 

Press the key to access the MENU page

User’s manual HANDHELD TOUCH RADIO

User’s manual HANDHELD TOUCH RADIO

Pag.24 

Pag.25 

Vers. 01 of:07.04.14

Vers. 01 of:07.04.14

5

2

1

3

6

1

Settable switch-on program

2

Settable switch-off program

3

Day of the week with active program

4

Number of "chrono" program (1-2-3-4)

5

Setting the power upon programming

6

Setting ambient temperature

4

MENU

MENU

CHRONO

ENABLE CHRONO

ENABLE CHRONO

SET CHRONO 

SET CHRONO 

SET CHRONO 

SET CHRONO

SET CHRONO 1

SET CHRONO 2

SET CHRONO 3

SET CHRONO 4

ENABLE CHRONO

ENABLE CHRONO

CHRONO

USER

MANUFACTURER 

ENGINEER

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

AIR-PELLET SET

STOVE STATE

MENU

Flow

Flow

Flow

Flow

MANUFACTURER 

ENGINEER

USER

USER

USER

SCREW FEEDING

SCREW FEEDING

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

USING THIS METHOD, IT IS NECESSARY TO VERIFY THAT AFTER EACH AUTOMATIC SHUTDOWN  

THE GRATE IS ALWAYS VERY CLEAN TO GUARANTEE CORRECT AUTOMATIC SWITCH ON.  

AUTOMATIC SWITCH ON.   

The first setting allows the activation of the CLIMATE COMFORT function. This function is intended to ensure that the room tem 

-perature set is maintained steady upon setting the maximum period of “X” minutes (SWITCH-OFF DELA 

Y: 5 MIN) before switch-ing to ECO STOP phase. The STOVE maintains this state until the temperature drops below the set 

value (CLIMATE COMFORT  DELTA : 5℃).  

For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is 

reached and restarts when  the temperature reaches 15°C (21°C - 5°C - 0,5°C tolerance).  

You can also activate the function using an external thermostat, keeping in mind that this does not include the value of the hyster 

-esis.  

We recommend you use an external thermostat with a histeresys value that can be set to maximum 3°C. 

The operation of the stove could activate the switch ON/OFF phases for several times during the day; 

this may affect the  service life of the ignition coil.  

Description of menu functions  

Press the key to access the MENU page  

The TECHNICIAN and MANUFACTURER menus are protected by password.  

Chronothermostat 

With the Chrono-thermostat function you can program the automatic switch ON/OFF of the stove for each day of the week  

for each day of the week in 4 independent time intervals (SET CHRONO 1-2-3-4) 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

CRONO-THERMOSTAT.   

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

By pressing the Increment key you can change each value and, at step 3, enable the days of the week; 

Press “confirm” to confirm the settings and switch to the next value; 

Press the “back” button to return to the CHRONO-THERMOSTAT page.  

As per the above example, it has been set as CHRONO 1 an ignition from 08.30 to 21.30 from MONDAY to  FRIDAY at the oper

-

ating power 5 with a room temperature set at 21 ° C. Programmes 2-3-4 can be set in the same manner.   

            To exit the CHRONO-THERMOSTAT function and return to Stand-by page, press the button repeatedly.  

AIR / PELLETS setting 

Setting of the PELLET-FLOW mix enables you to immediately change the quantity of pellet loaded in the brazier and the air inflow.  

The stove is tested and inspected with DIN PLUS certified pellets. If using another type of pellets or uncertified pellets, fuel may  

need adjustment. Usually, the variation involves the FLOW  percentage to adjust the input air and, therefore, the combustion; should 

the regulation of flow be insufficient, it may be necessary  to also change the percentage of PELLET load. 
Below are given the steps for accessing the relative menu starting from Stand-By mode.  

Press the key  “access 

menu” to access  

the  

MENU page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  

“selection”  

to quickly switch to 

SET  AIR  /  PELLETS.   

As per the above example, you have set a percentage of -2 for PELLETS and +3 for the FLOW 

, an indication 

that a setting like this  is a consequence of the fact that the oxygen needed for combustion is insufficient and pellet 

size is smaller than the average size of  2 cm.  

To exit the  SET AIR - PELLET function and return to Stand-by page, press the button repeatedly.  

NOTE: The number indicated during the change of parameters refers only to a percentage value that acts on the default  

parameters set on the electronic board (exclusively in the WORK phase). These values should be changed in the event  

of poor combustion, due in many cases to the purchase of pellets differing from those used during stove testing.   

 

📌

The TECHNICIAN and PRODUCER menus are password protected. Changing parameters within these menus could 

compromise the operation and safety of the stove. In this case the warranty will be invalidated.

MENU

USER

TECHNICIAN

PRODUCER

Summary of Contents for Flexi 9

Page 1: ...USE AND MAINTENANCE MANUAL Flexi 7 Flexi 9...

Page 2: ...hermostat room temperature control No Useful efficiency NCV as received with electronic room temperature control No Useful efficiency at nominal heat output th nom 94 4 with electronic room temperatur...

Page 3: ...room temperature control No Useful efficiency NCV as received with electronic room temperature control No Useful efficiency at nominal heat output th nom 93 5 with electronic room temperature control...

Page 4: ......

Page 5: ...do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove For further informatio...

Page 6: ...gations and forbidden actions 14 Characteristics of the fuel 15 TECHNICAL CHARACTERISTICS 16 Technical Data 16 Minimum clearances from combustible materials 17 Measurements 17 Technical diagram Flexi...

Page 7: ...nce of ignition phases 36 Modulation 36 Description of menu functions 36 Setting 39 Ventilation menu 41 Single ducting 41 Stove phase general layout 44 Warning Pop Up 45 Alarms table with reference co...

Page 8: ...ollowing harmonised standards and or technical specifications have been applied EN 14785 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 60335 1 EN 60335 2 102 EN 62233 EN 50581 ETSI EN 300220 1 Al...

Page 9: ...tzungsanweisungen Distanza minima da materiali infiammabili Minimum distance from flammable materials Distance moindre de mat riels inflammables Distancia minima de materiales inflamables Minimale afs...

Page 10: ...glass the gaskets the paint job the stainless steel or cast iron combustion grille the resistance the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of...

Page 11: ...re if any inconsistency arises it will be necessary to follow the text in the original language or contact our Technical Documentation Office Symbols used in the manual symbol definition This symbol i...

Page 12: ...e Only use original spare parts Any tampering and or replacements that have not been authorised by Ravelli can pose a danger to the user s safety In the event of particularly adverse weather condition...

Page 13: ...the contract and herein the operating manual procedures are followed routine maintenance is carried out according to the times and methods set forth extraordinary maintenance is promptly carried out...

Page 14: ...o a regulation chimney provide a suitable system for the supply of combustion air air intake or intake duct for watertight appliances always perform maintenance with the appliance off and cold perform...

Page 15: ...r of 6 mm and a variable length between 10 and 40 mm Their density is equal to approximately 650 kg m3 Due to their low water content 10 they have a high energy content The UNI EN ISO 17225 2 2014 sta...

Page 16: ...125 Smoke flow g s 3 0 3 7 3 0 4 4 Minimum draft Pa mbar 8 10 0 08 0 1 9 10 0 09 0 1 Electrical connection Hz V 50 230 50 230 Electrical power consumption max W 320 320 Electrical power consumption r...

Page 17: ...side mm 200 200 L Left side mm 200 200 B Rear mm 200 200 A Front mm 1000 1000 Measurements Unit of measurement Flexi 7 Flexi 9 D co Flexi 9 Glass Flexi 9 Steel Height mm 1050 1050 1050 1050 Width mm 5...

Page 18: ...Use and maintenance manual Flexi 7 Flexi 9 Pag 18 Rev 0 01 03 2023 EN Technical diagram Flexi 9 530 1050 530 574 574 80 CANALIZATION 395 50 AIR INLET 130 80 SMOKE OUTLET 192 305 72 5...

Page 19: ...the sofa using the handheld remote control Ravelli s patented cleaning system minimises maintenance by the user There is no longer any need to clean the brazier before each lighting and all maintenanc...

Page 20: ...uching the CONFIRM button you can read the detail of the warning doors and ash pan open If the combustion chamber door the pellet hopper lid and or the ash drawer are not closed within 1 minute the st...

Page 21: ...rical system of the house is up to standard equipped with a grounding circuit and all the safety systems required by the standards It should be noted that the stove s operating program has been design...

Page 22: ...1 1 DISEG VERIF APPR FABB Qual SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO R...

Page 23: ...talled that the safety distances from flammable materials are observed Verification of system compatibility has a priority over any other assembly or installation operation Local administrative regula...

Page 24: ...the Manufacturer Do not connect the appliance to a collective chimney The chimney must be built applying the following regulations it must observe product standard EN 1856 1 it must be made of materi...

Page 25: ...ion in the presence of other combustion appliances or VMC system it is necessary to check the appliance for correct operation The appliance must be placed inside living quarters It must never be insta...

Page 26: ...re is another one installed so that the outside section can be inspected It is prohibited to install two 90 bend since the ashes would quickly obstruct smoke passage causing draught problems in the ap...

Page 27: ...ld quickly obstruct smoke passage causing draught problems in the appliance See Fig 2 INTERNAL CHIMNEY Fig 5 Protection from rain Covering sheet Air tight steel sheet metal T fitting with collection c...

Page 28: ...stove s power cable must only be connected after the installation and assembly has been completed of the appliance and must remain accessible after installation To make the electrical connection proc...

Page 29: ...f the ducting pipe to avoid heat dispersion It is compulsory to connect the stove to the duct of the house before lighting Make sure that it is not possible to touch the fan blades installing the nece...

Page 30: ...AC 2 1 E S A F O R T U E N M1 M2 M3 T1 T2 T3 S2 S3 G2 S4 R1 G1 G1 G3 M4 Generico G1 Encoder lettura giri estrattore G2 Conta colpi pulitore automatico G3 Palmare Radio Touch S2 External thermostat S3...

Page 31: ...ure switch T2 Resettable thermal breaker T3 Pellet tank contact Motors M1 Auger gear motor M2 Automatic cleaning system M3 Flue gas fan M4 Room fan M5 Ducting fan Resistance R1 Igniter Probes S1 Flue...

Page 32: ...his reason on display appears the following message If the handheld set is used for the first time select YES using the selection keys and confirm with the dedicated key On the display of the handheld...

Page 33: ...cover of the battery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the remote control and observe the poles Instal...

Page 34: ...ERSION ADJUST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Moreove...

Page 35: ...DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NOT POWERED...

Page 36: ...contact therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to acce...

Page 37: ...perature If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRONO CHRO...

Page 38: ...ER WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance shoul...

Page 39: ...SION FW VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the thermostat...

Page 40: ...u will confirm of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window and the...

Page 41: ...erating modes manual and automatic Manual mode the user manually sets distribution of warm air between front ventilation and ducting Automatic mode the stove automatically manages distribution of warm...

Page 42: ...from three options EQUAL if the cubature of the two rooms is more or less the same REAR if the cubature of the room with ducting is larger than the one with the stove FRONT if the cubature of the roo...

Page 43: ...ion it is possible to set the room temperature reached by the ducting and the speed of the fans Press the increase decrease keys to modify the setting Press the confirm key to confirm the new setting...

Page 44: ...ture set is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTART The...

Page 45: ...the Support Service If the problem persists contact the Support Service AL 04 FAN BROKEN Fume exhaust encoder is not working or is connected incorrectly Contact the Support Service No power to fume e...

Page 46: ...tage AL 15 AUGER TRIAC An internal part of the electronic board that controls the pellet auger is faulty Check the flue is free and clean Possible voltage drops or incorrect input voltage Check the ma...

Page 47: ...g 47 Rev 0 01 03 2023 EN EXTERNAL POWER SUPPLY WITH MICRO USB CONNECTOR WIFI MODULE BOARD WITH CONNECTORS FOR EXTERNAL POWER SUPPLY CONNECTION Wifi kit Wifi external power supply kit if applicable MOT...

Page 48: ...martphone tablet entrare nel menu Android Impostazioni Connessioni Wi Fi iOS Impostazioni Wi Fi Selezionare la rete WINET XXXXXXXX ed inserire la chiave WPA indicata nell etichetta del dispositivo wi...

Page 49: ...odel name e g KTR AIR and then click Yes The screen offers a list of firmware once you have identified your model click on Select Yes Close the App and go to step 6 to register the account 4 CONNECTIO...

Page 50: ...open where you can register the WiFi device WiFi device registration When you click the link in the confirmation E mail the window to register the new device will open click Register your wifi device...

Page 51: ...l number and give the module a name e g living room stove STEP 3 complete with your information click Next and then Complete registration STEP 2 enter the product serial number and give the module a n...

Page 52: ...e pellet the stove operating mode and combustion control can affect maintenance activity frequency Cleaning Perform the cleaning operations so as to guarantee correct stove operation The table below l...

Page 53: ...emove them if necessary Extraordinary maintenance Extraordinary maintenance activities must be carried out by staff from the Authorised Assistance Centre Do not wait for components to be deteriorated...

Page 54: ...F APPR FABB Qual SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO REVISIONE TITOLO...

Page 55: ...tches 3 Clean the ashes eventually use a brush or similar and reassemble everything Note the hatches are equipped with gaskets therefore before reassembling them make sure that the gaskets are not wor...

Page 56: ...valves at the inlet and outlet for prolonged downtime DISPOSAL AT END OF SERVICE LIFE Warnings for the correct disposal of the product Demolition and disposal of the appliance is under the exclusive l...

Page 57: ...Displays Sensors Spark plugs Electronic boards Batteries Dispose of separately at authorised centres in accordance with WEEE 2012 19 EU and its national transposition E METAL STRUCTURE Dispose of sep...

Page 58: ...r s parer cet appareil et ou les piles ou les accumulateurs des autres types de d chets et de le confier au service municipal de collecte On peut demander au distributeur de pr lever le d chet d appar...

Page 59: ...r at forebygge ventuelle skader for milj et eller sundheden bedes brugeren om at behandle dette udstyr og eller de medf lgende batterier eller akkumulatorerne separat fra andre affaldstyper og at leve...

Page 60: ...free to make any variations to the features of its products without notice Aico S p A Headquarter Via Consorzio Agrario 3 D 25032 Chiari BS Italy Research and Development Centre Viale del commercio 1...

Reviews: