Use and maintenance manual Flexi 7 - Flexi 9
Pag.46
Rev.0 01/03/2023
EN
AL 08 DEPRESSION
The flue is blocked.
Check the flue is free and clean
The vacuum meter is faulty.
Check the mains voltage.
AL 12
FUME
EXHAUST
SYSTEM
The fume exhaust system has a loss of
performance due to fan obstruction or voltage
drop.
Check the mains voltage.
AL 14 AUGER
PHASE
No cable connection to power the gear motor
Check the mains voltage.
AL 15 AUGER TRIAC
An internal part of the electronic board that
controls the pellet auger is faulty.
Check the flue is free and clean
Possible voltage drops or incorrect input
voltage
Check the mains voltage.
AL 19 CLEANER
FAILURE
The cleaner did not complete the movement
and is not in the correct position
Reset the alarm and wait for the stove to switch to
SHUTDOWN mode. Cut off and power again, the
system reactivates the cleaner searching the correct
position again.
If the problem persists, contact the Support Service
AL 25 AUGER
ALARM
Anomaly in auger geared motor operation.
Contact the Support Service