The top of the display shows the front ventilation speed. The bottom of the display shows the ducting output, which can be modified with
the “increase/decrease” keys. The value which can be set goes from 0 (ducting off) to 5. Set at A (auto) the output of the fans follows the
output of the stove.
📌
In “manual” mode only the VENTILATION menu is accessible.
Automatic management
To enable automatic management, the ventilation and ducting speeds must be set to A (auto).
With this function, when activated, the stove manages power, ventilation and ducting independently, based on the set temperatures.
📌
To use automatic mode, two room temperature probes (optional) or external thermostats must be installed in the rooms to
be ducted.
Temperature
The following are the steps to be followed to access the TEMPERATURE menu, starting from the “Home” screen.
To exit the screen to go back to the CANALIZED menu, press the “back” key once; to go back to the Home screen, press
the “back” key several times.
📌
The room temperature can be set from the “Home” screen.
Cubature
To optimise automatic mode, set the cubature difference (m
3
) of the rooms.
you may choose from three options:
= EQUAL: if the cubature of the two rooms is more or less the same;
+ REAR: if the cubature of the room with ducting is larger than the one with the stove;
+ FRONT: if the cubature of the room with ducting is smaller than the one with the stove;
this way the stove will distribute more output to the larger room.
Press the
“Access to menu” key to
access the MENU screen
Press the
“confirm” key
to access the
USER screen
Press the “confirm” key
to go to the item CANALIZED.
Press the “selection” key to go to the
item CUBATURE
MENU
USER
TECHNICIAN
PRODUCER
USER
CANALIZED
LOADING AUGER
CHRONOTHERMOSTAT
SET AIR-PELLET
CANALIZED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBAGE
STATUS DISPLAY
Press the
“Access to menu” key to
access the MENU screen
Press the “confirm” key
to access the USER screen
Press the
“increase/decrease” keys
to modify ducting temperature.
Press the “confirm” key to go to the
item ENABLE EXT.T.
Enabling is carried out by pressing
the “confirm” key
Press the “confirm” key to go to the
item CANALIZED.
Press the “selection” key to go to the
item TEMPERATURE
Press the key to save the pa-
rameter and to go back to the
CANALIZED MENU screen
T. REAR
T. REAR
T. REAR
T. REAR
MENU
USER
TECHNICIAN
PRODUCER
USER
CANALIZED
LOADING AUGER
CHRONOTHERMOSTAT
SET AIR-PELLET
CANALIZED
MANAGEMENT
TEMPERATURE
VENTILATION
CUBAGE
STATUS DISPLAY
ENABLE T.EXT
ENABLE T.EXT
ENABLE T.EXT
ENABLE T.EXT