AL 08 DEPRESSION
The flue is blocked.
Check the flue is free and clean
The vacuum meter is faulty.
Check the mains voltage.
AL 12 FUME
EXHAUST
SYSTEM
The fume exhaust system has a loss of
performance due to fan obstruction or voltage
drop.
Check the mains voltage.
AL 14 SCREW
PHASE
No cable connection to power the gear motor
screw
Check the mains voltage.
AL 15 SCREW TRIAC An internal part of the electronic board that
controls the pellet infeed screw is faulty.
Check the flue is free and clean
Possible voltage drops or incorrect input
voltage
Check the mains voltage.
AL 19 CLEANER
FAILURE
The cleaner did not complete the movement
and is not in the correct position
Reset the alarm and wait for the stove to switch to
SHUTDOWN mode. Cut off and power again, the
system reactivates the cleaner searching the correct
position again.
If the problem persists, contact the Support Service
AL 25 SCREW
ALARM
Anomaly in auger geared motor operation.
- Please contact the Service Department.