Use and maintenance manual Flexi 7 - Flexi 9

Pag.20 

Rev.0  18/05/2020

TECHNICAL CHARACTERISTICS 

U

Flexi 7

Flexi 9

Energy efficiency class

- -

A++

A+

Heating input reduced - nominal

kW

3,4 - 7,4

3,4 - 9,1

Heating output reduced - nominal

kW

3,3 - 6,9

3,3 - 8,3

Red. - Nom. Yield 

95,5 - 92,9

95,5 - 90,6

Hourly consumption

kg/h 

0,71 - 1,53

0,71 - 1,87

Loading interval

h

11 -24

9 -24

Max. heating volume

m

3

165

195

CO at 13% of O

2

0,018 - 0,004

0,018 - 0,004

mg/m3

221 - 48

221 - 44

OGC at 13% of O

2

mg/m3

3 - 1

3 - 2

NO

X

 at 13% of O

2

mg/m3

129 - 126

129 - 140

PM at 13% of O

2

mg/m3

15,0 - 14,3

15,0 - 14,9

Smoke temperature  

 

°C 

73 - 129

73 - 163

Smoke flow

g/s 

3,0 - 4,6

3,0 - 5,7

Minimum draft

Pa - mbar

6 - 10

0,06 - 0,1

6 - 10

0,06 - 0,1

Electrical connection

Hz - V

50- 230 

50- 230 

Electrical power consumption max. 

W

360

360

Electrical power consumption reduced - 

nominal

W

18- 26

18- 26

Stand-by electrical consumption

W

2,3

2,3

smoke air inlet Ø

mm

50

50

smoke outlet pipe Ø

mm

80

80

Hopper capacity

kg

17

17

Seasonal energy efficiency 

%

90,1

87,9

Type of room temperature control

with electronic room temperature control plus week 

timer

Other control options

with distance control option

The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used. 

Ravelli reserves the right to make any changes in order to improve product performance.

Minimum clearances from combustible materials

Flexi 7

Flexi 9

Right side

150 mm

150 mm

L

 

Left side

150 mm

150 mm

B

 

Rear

100 mm

100 mm

A

 

Front

> 800 mm

> 800 mm

L

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

J

J

K

K

L

L

M

M

N

N

P

P

R

R

T

T

24

24

23

23

22

22

21

21

20

20

19

19

18

18

17

17

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DISEG.

VERIF.

APPR.

FABB.

Qual.

SE NON SPECIFICATO:

QUOTE IN MILLIMETRI

FINITURA SUPERFICIE:

TOLLERANZE:

   LINEARE:

   ANGOLARE:

FINITURA:

INTERRUZIONE 

BORDI NETTI

NOME

FIRMA

DATA

MATERIALE:

NON SCALARE DISEGNO

REVISIONE

TITOLO:

N. DISEGNO

SCALA:1:5

FOGLIO 1 DI 1

A0

PESO: 

80016CR01

A

R

B

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

J

J

K

K

L

L

M

M

N

N

P

P

R

R

T

T

24

24

23

23

22

22

21

21

20

20

19

19

18

18

17

17

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DISEG.

VERIF.

APPR.

FABB.

Qual.

SE NON SPECIFICATO:

QUOTE IN MILLIMETRI

FINITURA SUPERFICIE:

TOLLERANZE:

   LINEARE:

   ANGOLARE:

FINITURA:

INTERRUZIONE 

BORDI NETTI

NOME

FIRMA

DATA

MATERIALE:

NON SCALARE DISEGNO

REVISIONE

TITOLO:

N. DISEGNO

SCALA:1:5

FOGLIO 1 DI 1

A0

PESO: 

80016CR01

Summary of Contents for Flexi 7

Page 1: ...USE AND MAINTENANCE MANUAL Flexi 7 Flexi 9...

Page 2: ......

Page 3: ...saanwijzing Beachten Sie die Warnungen und Hinweise betreffend die Installation und regelm ige Wartung in der Bedienungsanleitung Respete las advertencias y las indicaciones de instalaci n y mantenimi...

Page 4: ...saanwijzing Beachten Sie die Warnungen und Hinweise betreffend die Installation und regelm ige Wartung in der Bedienungsanleitung Respete las advertencias y las indicaciones de instalaci n y mantenimi...

Page 5: ...The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report K21932020E7 8 Declared perf...

Page 6: ...d The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report K21932020E7 8 Declared pe...

Page 7: ...rd The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report K21932020E7 8 Declared p...

Page 8: ...rd The notified laboratory T V Rheinland Energy GmbH NB 2456 performed the determination of the product type on the basis of type testing under system 3 and issued test report K21932020E7 8 Declared p...

Page 9: ...rademark Marque Ravelli Modello Model Mod le Flexi 7 L oggetto della dichiarazione di cui sopra conforme alla pertinente normativa di armonizzazione dell Unione The object of the declaration described...

Page 10: ...Po le granul s de bois Ravelli Flexi 9 Dec Flexi Glass Flexi Steel L oggetto della dichiarazione di cui sopra conforme alla pertinente normativa di armonizzazione dell Unione The object of the declara...

Page 11: ...or the smoke evacuation system 25 Chimney 26 Chimney pot 26 Installation 26 Requirements for the installation premises 27 Installation example for a stove pellet stove 28 Connections 30 Chimney connec...

Page 12: ...chamber cleaning 54 To clean the pellet tank proceed as follows 54 Extraordinary maintenance 54 Deep combustion chamber cleaning 54 Checking the seals 55 Smoke conduit cleaning 55 STORAGE AND DISPOSAL...

Page 13: ...do not discard it without reading it Incorrect installation maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove For further informatio...

Page 14: ...30 7402939 Fax 39 030 7301758 www ravelligroup it info ravelligroup it Reference standards The Flexi 7 Flexi 9 stoves that this manual refers to are compliant with the regulation 305 2011 CONSTRUCTION...

Page 15: ...defects as long as the product has not broken sue to an incorrect use negligence incorrect connection tampering installation errors The warranty becomes null and void even if only one requirement in t...

Page 16: ...ice Symbols used in the manual symbol definition This symbol is used to identify particularly important information in the manual This information also concerns the safety of users involved in using t...

Page 17: ...integrated into the stove s design and construction as much as possible For every residual risk there is a description of the risk and the zone or part that is applies to unless the risk applies to th...

Page 18: ...isation the use is considered improper Any contractual and non contractual liability of the manufacturer is excluded for damages to persons animals or property due to installation and maintenance adju...

Page 19: ...and a variable length between 10 and 40 mm Their density is equal to approximately 650 kg m3 Due to their low water content 10 they have a high energy content The UNI EN ISO 17225 2 2014 standard that...

Page 20: ...nd by electrical consumption W 2 3 2 3 smoke air inlet mm 50 50 smoke outlet pipe mm 80 80 Hopper capacity kg 17 17 Seasonal energy efficiency 90 1 87 9 Type of room temperature control with electroni...

Page 21: ...ALI SECONDO LA CLASSE UNI EN 22768 mK GENERAL TOLERANCES AS PER UNI EN 22768 mK FORMATO SCALA DISEGNATO MASSA DATA GRUPPO DI APPARTENENZA TIPOLOGIA 1 10 A3 05 05 2020 Assieme Assemblato Propriet della...

Page 22: ...MATO SCALA DISEGNA MASSA DATA GRUPPO DI APPARTENENZA TIPOLOGIA 1 10 A3 04 05 2020 Assieme Assemblato Propriet della Societ AICO S p A Senza autorizzazione scritta della stessa il presente disegno non...

Page 23: ...using the handheld remote control Ravelli s patented cleaning system minimises maintenance by the user There is no longer any need to clean the brazier before each lighting and all maintenance operati...

Page 24: ...1 1 DISEG VERIF APPR FABB Qual SE NON SPECIFICATO QUOTE IN MILLIMETRI FINITURA SUPERFICIE TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO RE...

Page 25: ...ot create a vacuum in the room where the stove is installed that the safety distances from flammable materials are observed Verification of system compatibility has a priority over any other assembly...

Page 26: ...ical and not feature any bottlenecks along its entire length it must be correctly spaced with an air gap and insulated from flammable materials there must be a maximum of 2 changes in direction and an...

Page 27: ...or the power of the appliance and in any case greater than 15 m3 When extraction fans example extraction hoods are used in the same room or space as the stove this can cause problems to stove operatio...

Page 28: ...talled externally there is another one installed so that the outside section can be inspected It is prohibited to install two 90 bend since the ashes would quickly obstruct smoke passage causing draug...

Page 29: ...segment since the ashes would quickly obstruct smoke passage causing draught problems in the stove See Fig 2 INTERNAL CHIMNEY Fig 5 Protection from rain Covering sheet Air tight steel sheet metal T fi...

Page 30: ...the appliance and must remain accessible after installation To make the electrical connection proceed as described below First connect the power cable to the plug on the back of the stove and then to...

Page 31: ...be protected by using insulating materials or taking appropriate measures It is recommended to insulate the entire length of the ducting pipe to avoid heat dispersion It is compulsory to connect the s...

Page 32: ...o G3 Palmare Radio Touch S3 Room probe General G1 Extractor revolution reading encoder G2 Automatic cleaner control contact G3 Handheld set Radio Touch G n rique G1 Encoder lecture tours extracteur G2...

Page 33: ...K POWER It is possible to use button 2 to change the delivered heat power In order to increase power press P2 once again Power LED 3 set on work power 1 Power LED 3 set on and flashing 4 work power 2...

Page 34: ...control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the handheld set and observe the poles Install the battery protective cover as shown in figur...

Page 35: ...ment it is not necessary to perform the initialization procedure of the handheld computer In this case when the display will show the message FIRST INSTALLATION select NO and press the dial key Descri...

Page 36: ...ress the key access menu to access the MENU page Press the key confirm to access the SETTINGS page Press the key confirm to access the USER page Press the key con firm to access the page DATE TIME Pre...

Page 37: ...ld you can switch the appliance on off using the appropriate button on the electronic board The brazier is mechanically cleaned before each ignition except after the initial screw feed and in case of...

Page 38: ...DHELD TOUCH RADIO Pag 24 Vers 01 of 07 04 14 MENU USER MANUFACTURER ENGINEER USING THIS METHOD IT IS NECESSARY TO VERIFY THAT AFTER EACH AUTOMATIC SHUTDOWN THE GRATE IS ALWAYS VERY CLEAN TO GUARANTEE...

Page 39: ...equests T C Boiler From STAND BY mode press the ARROW key UP to set the room T C and DHW boiler T C that you desire Boiler water T C From STAND BY mode press the ARROW key DOWN to set the boiler water...

Page 40: ...BLE COMFORT COMFORT CLIMA DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CON...

Page 41: ...E THERMOSTAT ENABLE THERMOSTAT ENABLE EXT T ENABLE EXT T ENABLE EXT T ENABLE EXT T SEASON SEASON SEASON SEASON CONTRAST CONTRAST CONTRAST CONTRAST FW VERSION FW VERSION FW VERSION FW VERSION LANGUAGE...

Page 42: ...he value read by the room temperature probe installed inside the handheld set with respect to a reference value The value can vary from 10 C to 10 C The standard value is 0 C By pressing the following...

Page 43: ...AUTO function and activate by confirming V Press the confirm key to go to the MANUAL or AUTOMATIC selection screen Ventilation manual mode Press the Access to menu key to access the MENU screen Press...

Page 44: ...ress the confirm key to go to the item CANALIZZATA DUCTED Press the selection key to go to the item TEMPERATURE Press the key to save the parameter and to go back to the DUCTED MENU screen Press the A...

Page 45: ...e item CANALIZZATA DUCTED Press the selection key to go to the item VISUALIZZA STATO VIEW STATUS 4 2 1 1 Cubature priority active in automatic mode 2 Ducted ventilation setting 3 Ducted temperature se...

Page 46: ...temperature set is reached see the dedicated section START RESTART WAIT Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically SWITCH ON RESTA...

Page 47: ...the Support Service AL 04 FUME EXHAUST DAMAGED Fume exhaust encoder is not working or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service The f...

Page 48: ...15 SCREW TRIAC An internal part of the electronic board that controls the pellet infeed screw is faulty Check the flue is free and clean Possible voltage drops or incorrect input voltage Check the mai...

Page 49: ...tphone tablet entrare nel menu Android Impostazioni Connessioni Wi Fi iOS Impostazioni Wi Fi Selezionare la rete WINET XXXXXXXX ed inserire la chiave WPA indicata nell etichetta del dispositivo wi fi...

Page 50: ...l name e g KTR AIR and then click Yes The screen offers a list of firmware once you have identified your model click on Select Yes Close the App and go to step 6 to register the account 4 CONNECTION T...

Page 51: ...n where you can register the WiFi device WiFi device registration When you click the link in the confirmation E mail the window to register the new device will open click Register your wifi device now...

Page 52: ...umber and give the module a name e g living room stove STEP 3 complete with your information click Next and then Complete registration STEP 2 enter the product serial number and give the module a name...

Page 53: ...intenance is finished re install all of the dis assembled parts before restarting operation The quality of the pellet the stove operating mode and combustion control can affect maintenance activity fr...

Page 54: ...by use before proceeding with their replacement Replace a worn component before it is completely broken to prevent any damage caused by sudden component breakage PARTI FREQUENZA 1 STAGIONE Deep combus...

Page 55: ...Note The operation must be carried out when the stove is cold using an ash vacuum cleaner A B C D E F G H J K L M N P R T 24 24 23 23 22 22 21 21 20 20 19 19 18 18 17 17 16 16 15 15 14 14 13 13 12 12...

Page 56: ...TOLLERANZE LINEARE ANGOLARE FINITURA INTERRUZIONE BORDI NETTI NOME FIRMA DATA MATERIALE NON SCALARE DISEGNO REVISIONE TITOLO N DISEGNO SCALA 1 5 FOGLIO 1 DI 1 A0 PESO 80016CR01 A B C D E F G H J K L M...

Page 57: ...d not obstructed make sure the chimney is sized for the stove power make sure that the air intake in the room is clear of any obstructions and that there are no other combustion appliances or extracti...

Page 58: ...r s parer cet appareil et ou les piles ou les accumulateurs des autres types de d chets et de le confier au service municipal de collecte On peut demander au distributeur de pr lever le d chet d appar...

Page 59: ...r at forebygge ventuelle skader for milj et eller sundheden bedes brugeren om at behandle dette udstyr og eller de medf lgende batterier eller akkumulatorerne separat fra andre affaldstyper og at leve...

Page 60: ...y errors in this booklet and considers itself free to make any variations to the features of its products without notice Aico S p A Via Kupfer 31 25036 Palazzolo sull Oglio BS ITALY Tel 39 030 7402939...

Reviews: