DECLARATION OF PERFORMANCE
Declaration of performance according to Regulation (EU) 305/2011
n. : 252CPR13.07
1.
Unique identification code of the product type:
L0005GC01, residential space heating appliance fired by solid fuel
EN13240:2001/A2:2004/AC:2007
2.
Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4):
CALLIOPE VIEW EU
3.
Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer:
Residential space heating appliance fired by solid fuel
4.
Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5):
Ravelli
On behalf of:
Aico S.p.A.
via Kupfer, 31
25036, Palazzolo sull’oglio (BS)
- Italia
by:
Scan A/S
Glasvænget 3-9
5492 Vissenbjerg DK
5.
Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):
---
6.
System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:
System 3
7.
In case of the declaration of performance concerning a construction product covered by a harmonised standard:
The notified laboratory Danish TI (NB 1235) performed the determination of the product type on the basis of type testing under system 3 and
issued test report 300-ELAB-2489-EN nom
8.
Declared performances:
Harmonized technical specification:
EN13240:2001/A2:2004/AC:2007
Essential characteristics
Performance
Fire safety
Reaction to fire
A1
Distance to combustible materials
Minimum distances (mm):
rear = 225
sides = 500
front = 1000
ceiling = --
floor = 0
Risk of burning fuel falling out
Pass
Emission of combustion products
(at 13% of O
2
)
Nominal heat output
CO 0,042 % - 522 mg/Nm
3
NOx 93 mg/Nm
3
OGC 31 mg/Nm
3
PM 13 mg/Nm
3
Surface temperature
Pass
Electrical safety
Pass
Cleanability
Pass
Maximum operating pressure
--
Flue gas temperature at nominal heat output
270 °C
Mechanical resistance(to carry a chimney/flue)
NPD
Nominal heat output
6,5 kW
Room heating output
6,5 kW
Water heating output
--
Efficiency
Ƞ
80 % Nominal heat output
9.
The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance is
issued under the sole responsibility of the manufacturer identified in point 4.
Signed for and on behalf of the manufacturer
Claudio Mezzalira, Operations Manager
Place
Vissenbjerg
Date
04/06/2020
Sign _______________