14
1.
Rear cover
2.
Gas control system
3.
Housing
4.
Protective cover
5.
Ceramic panel (burner)
6.
Fume analyser burner
7.
Castors
PLEASE NOTE!
The protective cover of this device prevents the risk of fire or scalds and it is not recommended to remove
any of its parts permanently.
THE PROTECTIVE COVER DOES NOT ENSURE COMPREHENSIVE PROTECTION FOR CHILDREN OR THE DISABLED!
Every cover or other protective device removed to inspect the heater must be installed before the heater
is switched on again.
B. TECHNICAL PARAMETERS
•
The heater is fueled with LPG G30 (propane-butane)
•
Supply pressure 37 mbar
•
Device category I
3B/P
•
Maximum heat output (gas consumption) 4.1 kW (298g/h)
•
Minimum heat output (gas consumption) 1.5 kW (109g/h)
•
Heater weight: 8.5 kg.
•
Dimensions: (depth) 36.5 x (width) 42 x (height) 73 cm
•
Minimum cubature of the heated room: 15m
3
•
Space for gas cylinder 11 kg
III. HEATER LOCATION
1.
The heater is designated for placing on the floor. Please ensure a distance from the walls and other
items. The heater location should ensure easy access to control parts (including the valve on the gas
cylinder).
2.
The heater must not be placed in passages so as it does not hamper circulation. Access to the heater
must not be obstructed with other objects.
3.
The heater should be placed in the location ensuring unrestricted air supply for combustion and fume
discharge. Do not place any chairs, armchairs etc. where people could rest for a longer time along the
fume discharge route.
4.
The minimum distance to be ensured while placing the heater:
•
The minimum distance to the rear and sides of the heater - at least 25cm
•
The minimum distance to the obstacles in front of the heater - at least 2m
•
Other sources of heat near the heater - at least 2m
5.
Do not install the heater in:
•
Bedrooms
•
Bathrooms, bathhouses, near swimming pools or in other places where the heater could
be exposed to water
•
In cars, caravans and campers
•
In places where the curtains, furniture, clothes or other flammable objects are located
closer than 2 m to the heater front, top or sides
•
As a fireplace insert
•
In rooms and places entered by wind or draughts (where the burner flame could
be blown out)