17
cannot be pressed or turned by hand, do not try to fix it. Call a service technician or gas provider. Using
force or attempted repairs can cause fire or gas explosion.
6.
Always ensure dry powder extinguisher or fire blanket ready to use nearby.
VIII. OPERATION
PLEASE NOTE!
Before lighting the heater, smell to device vicinity for the presence of fire. Gas can be smelled at the floor level
as LPG is heavier than air and keeps near the floor.
IF YOU SMELL ANY GAS:
•
Turn off all the gas valves immediately
•
Put out any open flame.
•
Do not turn on any gas or electric device
•
Do not touch any electric switches
•
Do not use a phone in the room
•
Call your gas provider immediately, by calling from your neighbour's phone. Follow the instructions
received from the gas provider
•
If it is impossible to contact the gas provider, call the fire brigade.
•
Whenever possible, open the windows or doors, or increase the ventilation in the room (remember
not to turn on any fans or any other devices increasing the air flow).
A. TO TURN THE HEATER ON
1.
Turn off the cock on the gas cylinder.
2.
Press and turn the control knob to the lighting position.
3.
Press the control knob for 30 s. Pressing the control knob, press the starter button a couple of times,
until the starter flame appears. Stop pressing the control knob 10~20s after lighting.
PLEASE NOTE!
•
If a new cylinder has just been connected, wait at least 1 min or longer for the air in the gas circuit
to go out through the starter opening.
•
Lighting up the starter flame make sure the control knob is still pressed.
•
If the heater does not light up, repeat all the steps.
4.
Before setting a required temperature by means of the knob, leave the heater in position 1 for about
5 minutes.
5.
Selecting the required heating level, press the control knob lightly and turn it counterclockwise. Stop
pressing the control knob, turning it further until it is stopped in the required position. Do not tamper
with the pre-set position.
6.
The fume analyser will switch the heater off when the oxygen content in the air falls below 18%.
If such a situation is detected, close all the gas valves and ventilate the room. Before turning the device
on again, check whether the ventilation system in the room meets the requirements necessary for the
device to work.
B. TO TURN THE HEATER OFF
1.
Press and turn the knob to the lighting position.
2.
Turn off the valve on the gas cylinder.
A.
Starter
1.
Minimum output
2.
Average output
3.
Maximum output
B.
Control knob
C.
Lighting position
PL EAS E N OT E!