Spreading operation using the QUANTRON-K2 Control unit
67
5
5
Spreading operation using the QUANTRON-K2 Control unit
The QUANTRON-K2 Control unit supports you with the setting of your machine
before you start your work. During spreading, the functions of the Control unit are
also active in the background. With these functions, the spreading quality can be
checked.
5.1
Minimum mass flow
A symbol indicating a minimum mass flow can appear in the
operating screen
and the
Calibration
submenu when certain settings are made to the Single-disc
spreader.
If the mass flow has been set to less than the limit of 5 kg/min, the system will
automatically
spread using the minimum mass flow of
5 kg/min
.
In this case you
will not
spread with the spreading density you have set.
The actual spreading density exceeds the set spreading density.
Figure 5.1:
Warning symbol in the Calibration submenu and on the operating
screen
[1] Minimum mass flow symbol
You can calculate the mass flow using the following formula:
NOTICE
The minimum mass flow warning message only appears in the
MAN km/h
and
AUTO km/h
operating modes.
Mass flow (kg/min) =
spreading density
(g/m
2
)
x
Spreading
width (m)
x
Speed
(km/h)
60
1
Summary of Contents for QUANTRON-K2
Page 6: ...Table of Contents IV...
Page 10: ...User notices 1 4...
Page 26: ...Attachment and installation 3 20...
Page 72: ...Operation QUANTRON K2 4 66...
Page 90: ...Spreading operation using the QUANTRON K2 Control unit 5 84...
Page 94: ...Alarm messages and possible causes 6 88...
Page 96: ...Special equipment options 7 90...
Page 100: ...Index D...
Page 102: ......