Operating the AXMAT system
25
4
Continue driving until the progress bar is complete and the collecting vessels
have been completely driven over with the spreading pattern.
9.
Press
Start/Stop
.
Close the metering slide.
The machine control unit switches to the next calibration window.
10.
Press
Spreading disc start
.
The spreading discs stop.
11.
Check the results of the spreading test.
See
4.2.1: Evaluate the results and correct if necessary, page 25
4.2.1
Evaluate the results and correct if necessary
Results with 5 or 10 collecting vessels (working width up to 36 m)
Pool the contents of the collecting vessels placed one after another and pour
them into the measuring tubes from the left-hand side.
Read the quality of the horizontal spreading pattern via the filling levels of the
measuring tubes.
Figure 4.8:
Possible results
[A] All measuring tubes contain the same amount.
[B] The fertiliser distribution is not symmetrical.
[C] Too much fertiliser in the overlap zone
[D] Too little fertiliser in the overlap zone
A
100%
B
100%
C
100%
D
100%