Subsequently, the number of pulses of the forward speed signal has to be
defined. If the exact number of pulses is known, you can enter it directly:
5.
Call up the
Pulses/100m
menu item from the selected tractor profile.
The display shows the Pulses menu for the manual input of the pulse
count.
If you do
not know
the exact number of pulses, you can start a
calibration run
.
6.
Press the calibration key in the tractor profile.
The calibration run working screen is shown on the display.
7.
Press the
Start key
at the starting point of the reference track.
The pulse display is now zero.
The control unit is ready to count pulses.
8.
Drive along a 100 m long reference track.
9.
Stop the tractor at the end of the reference track.
10.
Press the
Stop key
.
The number of received pulses is displayed.
The new pulse count is saved.
This returns you to the profile menu.