Service messages SCC
26
27
28
1
1
1
2
2
2
29
30
31.1-6
1
1
1
2
2
2
32
33
34
1
1
1
2
2
2
NOTE:
- Appears on time after switch ON
- After 3x OFF - ON without successful
flame reset the unit will display
"No Function" in window 2
- 1: Ignition box top
- 2: Ignition box bottom
- Change ignition box
NOTE:
- Appears after 4x Reset command without
positive result
- After OFF - ON first open gas valve and
switch on exhaust hood
- 1: Ignition box top
- 2: Ignition box bottom
- Check ignition wire
- Check wire / plug from blower motor
to ignition box
Ch
i
iti
b
NOTE:
- Appears when Bus signal problem
- Hex code (Combination i.e.: 34.10, 2+8)
- 1: I/O PCB
- 2: Motor bottom
- 4: Motor top
- 8: Ignition module top
- 16: Ignition module bottom
- Check bus cable plug and cable for
connection and damage
Service 34.1-5
(BUS signal problem)
Switch OFF - ON
No function
No function
Service 32.1-2
(Ignition box)
Service 33.1-2
(4x Reset)
NOTE:
- Appears on time after switch ON until
temperature is low again
- Temperature PCB above 85°C
- Check air filter and cooling fan and
control panel gasket
- Check for external heat sources
NOTE:
- Appears for 2 min after switch ON
- Display can be cancelled by touch
- Humidity control out of function
- Humidity emergency control active
since more than 1 hour
NOTE:
- Appears for 2 min after switch ON
- Core sensor defective on 1- 4 points of 6
Change air filter
Maintenance needed
Maintenance needed
NOTE:
- Appears on time when CleanJet is selected
- Cooking not possible - drain closed
- Micro switch drain valve in permanent
closed position
- Check micro switch of drain valve
NOTE:
- Appears for 2 min after switch ON
- Display can be cancelled by touch
- Micro switch drain valve in permanent
open position, CleanJet not possible
- Check micro switch drain valve
- Start rinse (abort) program
NOTE:
- Appears after Thermocouple steam generator
B5
above >180°C (300°F)
- Display can be cancelled by touch
- Indication goes off when temperature
below 110°C (230°F)
Service 29
(PCB temperature)
Service 30
(humidity control)
Service 31.1-6
(core sensor)
Service 28
(Steam generator above 180°C)
No function
CleanJet Error
Maintenance needed
Service 26
(drain closed)
Service 27
(CleanJet micro switch)
II- 28
Summary of Contents for SelfCooking Center SCC