dP #
Connection
dP 1
dP 2
X 3
Reset by pressing
for 5 sec.
dP 3
X 4
Reset by pressing
for 5 sec.
dP 4
X 2
Reset by pressing
for 5 sec.
dP 5
X 6
Reset by pressing
for 5 sec.
dP 6
Reset by pressing
for 5 sec.
dP 7
X27:(1-2)
dP 8
X12:(1-4) S2
X19:(1-2) Y1
dP 9
dP 10
dP 11
BUS / RS485
dP 12
BUS / RS485
dP 13
X 20
dP 14
X 26
dP 15
dP 16
from version 01-06-03
dP 17
from version 01-06-03
Notes:
Flame Current Steam
x.x µA
Flame Current Hot Air
Top x.x µA
Bottom x.x
µA
max value
0 - 1 - 2
1 - 0
Software
version:
05.00
max value
max value
max value
max value
1 - 0
Y1
1 - 0
Service Level: dP -- Diagnostic
Description
Cabinet
display
Timer
display
1 - 0
Energy pulsing
Unit size and type
61 - 202
ELE - GAS
0 - 1 - 2
B5 Steam generator sensor
actual value
PCB temperature
actual value
S3 Door contact
S2 Water level steam
generator
S2
1 - 0
Actual rpm
Actual rpm
Speed fan motor bottom
Set rpm
Speed fan motor top
Set rpm
Software version
Software
version:
C - 1 -
B1 Cabinet sensor
actual value
Energy optimising input
B2 Quenching sensor
actual value
B3 Core sensor
actual value
Hot Air elements
0 - off; 1 - 50%; 2 - 100%
Temp B1
Steam elements
0 - off; 1 - 50%; 2 - 100%
Temp B5
I - 17
Summary of Contents for SelfCooking Center SCC
Page 29: ...Notes I 29...
Page 30: ...Notes I 30...
Page 31: ...Notes SCC Control panel 1 2 3 4 II 01...
Page 61: ...Notes Drain Valve Control II 31 Direction 1 Direction 2...
Page 68: ...Notes II 38...
Page 84: ...Notes III 16...