15 | Accessories
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB
87 / 92
15
Accessories
A detailed overview with article numbers can be found in the accessories cata-
logue.
Accessories
Description
Base frames UG I – IV
Different base frames, with or without support rails
for storage of accessories and partially closed. For
varying installation options, the base frames can be
extended with castors or fixable feet.
Left and right heat shield
If a sufficient distance to the heat source on the left
cannot be maintained, an additional heat shield is
available that reduces thermal loads.
For the unit sizes 6-1/1 GN and 10-1/1 GN an ad-
ditional heat shield is available for the right side.
Levelling frame for tabletop
units
If the installation surface is not level, use a levelling
frame to compensate this. The adjustment range is
+/- 20 mm [3/4 inches].
Unit elevation for tabletop units
Suitable for unit sizes 6-1/1 GN and 10-1/1 GN
with a minimum depth of 700 mm [27.6 inches].
If the distance to the worktop is too small, the unit
can be increased by 150 mm [5.91 inches].
Unit elevation for standalone
units
If the floor clearance for standalone units is insuffi-
cient, the clearance can be increased by elevating the
unit feet by 70 mm [2.76 inches].
Transport trolley for mobile
oven racks (Standard or Combi-
Duo)
Recommended for use with mobile oven racks. Two
variants for table-top units (Standard) or Combi-Duo
with different docking systems. Requires the correct
feed rail. The standard transport trolley is also avail-
able as height adjustable to compensate for height
differences in the installation.
Mobile oven rack elevation
If the unit feet on standalone units are increased with
a foot elevation, a mobile oven rack elevation (70
mm) [2.76 inches]) must be installed to compensate.
Entry ramp for standalone units
If the installation surface is not level in the mobile
oven rack entry area on standalone units, use an
entry ramp to compensate this. The plate feet are ad-
justable by +/- 10 mm [0.39 inches].
Condensation breaker
Extending the ventilation pipe without using a con-
densation breaker can cause the unit to malfunction.
Installing a condensation breaker and the included
pipes can divert steam escaping from the exhaust
pipe into non-critical areas, or towards the extrac-
tion range of a ventilation system.
Wall mounting
Tabletop unit sizes 6-2/3 GN and 6-1/1 GN can be
attached to the wall using a wall bracket.