5.4
Notes on extractor hood
DANGER
Toxic exhaust fumes
Risk of asphyxiation from unauthorised concentration of hazardous flue
gas.
n
Ensure that the ventilation options in the installation area are adequate.
n
Perform a flue gas analysis prior to commissioning the unit.
On-site ventilation
When installing an exhaust device, observe the following:
n
VDI Directive 2052, NFPA 96 and local construction authority regulations
on exhaust hoods.
n
The exhaust hood must protrude 300-500 mm [12 – 20 inches] over the
front of the unit.
n
Install the unit underneath an exhaust device if using a VarioSmoker.
n
Install a grease filter into the protruding part of the exhaust device.
Exhaust hood
Exhaust hoods are available for the units (including retrofitting). To install the
exhaust hood, follow the installation manual enclosed with the exhaust hood.