5 | Placement
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB
31 / 92
Minimum clearance ceiling
x [mm]
400
x [inch]
16
Condensation breaker
If steam from the ventilation pipe cannot be directed into an exhaust hood or a
ventilating ceiling, there must be a minimum clearance to the ceiling above the
unit.
This space is required to install a condensation breaker so that exhaust air can be
directed into non-critical areas.
Minimum clearance ceiling
x [mm]
500
x [inch]
20
5.2
Installation of tabletop units
WARNING
The unit is falling from the installation surface
Risk of crushing and injury from tipping or turning of the unit.
n
Do not tip the unit onto the installation surface.
n
When turning the unit, make sure that the weight of the unit is evenly
distributed and that all unit feet are on the installation surface.