6 | Electrical connection
56 / 92
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (1 NAC 240 V)
50/60
24
5.7
25
F
6-1/1 E (1 NAC 240 V)
50/60
48.8
11.7
50
F
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (2 AC 208 V)
60
28
5.7
30/35
B
6-1/1 E (2 AC 208 V)
60
53
10.8
60
B
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (2 AC 230 V)
50/60
23.1
5.3
25
B
6-1/1 E (2 AC 230 V)
50/60
47
10.8
50
B
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (2 AC 240 V)
50/60
24
5.7
25
B
6-1/1 E (2 AC 240 V)
50/60
48.8
11.7
50
B
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (2 AC 240 V)
50/60
32
5.7
35/40
B
6-1/1 E (2 AC 240 V)
50/60
61
10.8
70
B
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (3 AC 200 V)
50/60
15.9
5.3
16
B
6-1/1 E (3 AC 200 V)
50/60
29.2
10.1
32
B
6-2/1 E (3 AC 200 V)
50/60
60
20.8
63
B
10-1/1 E (3 AC 200 V)
50/60
50.5
17.5
63
B
10-2/1 E (3 AC 200 V)
50/60
99.9
34.6
100
B
20-1/1 E (3 AC 200 V)
50/60
99.6
34.5
100
B
20-2/1 E (3 AC 200 V)
50/60
181.9
63
200
B
Hz
Current
consump-
tion (A)
Power (kW) Fuse (A)
RCD type
6-2/3 (3 AC 208 V)
60
15.9
5.7
20
B
6-1/1 E (3 AC 208 V)
60
30
10.8
35
B
6-2/1 E (3 AC 208 V)
60
62.2
22.4
70
B
10-1/1 E (3 AC 208 V)
60
52.5
18.9
60
B
10-2/1 E (3 AC 208 V)
60
103.8
37.4
125
B
Summary of Contents for LM1 Series
Page 1: ...iCombi Pro iCombi Classic CombiMaster Plus Original installation manual...
Page 90: ......
Page 91: ......