Building services - steam generator descaling
92 / 107
step
info/button
instructions
10
Guide hose into steam inlet opening as far as
the mark.
Tip:
The allocation of marks to appliance size is
described in the instructions for the descaler
pump.
Warning!
Aggressive chemical fluid – risk of chemical
burns.
It is essential that you use:
protective clothing, safety goggles, gloves,
face mask and the appliance manufacturer‘s
descaler pump.
11
Insert hinging rack and fix hose with wire hooks.
Warning!
Aggressive chemical fluid – risk of chemical
burns.
There may be residues of the descaling fluid
in the hoses. Rinse the descaling accessories
thoroughly with water.
Please wear: protective clothing, safety goggles,
gloves, face mask
12
Place canister of descaling fluid in the cooking
cabinet and run the hose into the canister.
Tip:
Descaling fluid reacts with lime and can foam
over.
Very slowly fill with descaling fluid using the
appliance manufacturer’s descaling pump.
Summary of Contents for CombiMaster Plus CMP 61
Page 1: ...CombiMaster Plus CombiMaster Original operating instructions...
Page 79: ...Cleaning CombiMaster Plus 79 107...
Page 104: ...EU Declaration of Conformity 104 107...
Page 105: ...EU Declaration of Conformity 105 107...
Page 106: ...EU Declaration of Conformity 106 107...
Page 107: ......
Page 108: ...80 02 407 V 02 MDS Ad 09 17...