background image

Ratio ELECTRIC

www.ratio.nl

Press briefly the middle button to start. After starting, the charger is always ready 
to charge with the previous settings. If you want to change the settings enter the 
setup menu (see page 7 SETUP MENU)

READY TO

CHARGE

You can reach the next screen with the left or right arrow button. 
The menu’s below can be reached with the arrow button from a READY TO 
CHARGE screen but also from CHARGING screen.

Here you can find more information about the consumption:
 
I: 

current (A)

U: 

voltage (V)

P: 

power (kWh)

Et: 

total kWh value

 (cumulatieve,
 

you can’t reset it)

3   P H A S E   C H A R G E   S TAT I O N

I 1:  

A

I 2:  

A

I 3:  

A

U 1:  

V

U 2:  

V

U 3:  

V

P 1:  

kWh

P 2:  

kWh

P 3:  

kWh

Et:  

kWh

11

5

I N S T A L L A T I O N

1.

The installation must be done by a qualified and licenced electrician

according the local legislation.

2.

The electrical installation must be free of power during the entire

installation period.

3.

Since this Charging Unit uses circuits that reference to ground, no

Megging must be done after connecting to power.

4.

Wiring and protection:

Version

Wiring *

Mains Circuit Breaker 

(MCB)

Residual Current Device 

(RCD)

16A / 1 Phase

3G2,50mm

2

30mA, Type A

16A / 3 Phase

5G2,50mm

2

30mA, Type 

32A / 1 Phase

3G6,00mm

2

30mA, Type A

32A / 3 Phase

5G6,00mm

2

*

For cable length upto 25m

PLEASE NOTE:

All charges include an AC (> 30mA) and

DC (> 6mA) residual-current-detection.

Always place a type A RCD and the MCB (or 

combination unit) in the electrical cabinet.

5. 

Open bottom cover of the Charge Station

 

(5 screws – see picture). Carefully brake out

 

required cable opening for incoming power cable

 

and charge cable.

 

power cable from the back. Use supplied M25

6. 

Use 4 wood screws M4,5x35mm to mount Charging Station on the wall.

 

The Charging Station should be installed between 0,80m and 1,20m from

 

bottom to the ground.

HOME BOX PLUS / Version: EV045

Summary of Contents for HOME BOX PLUS

Page 1: ...M a n u a l HOME BOX PLUS EV CHARGING STATION ENERGY METER ...

Page 2: ...9 MAINTENANCE 9 FCC INFORMATION 10 WARRANTY INFORMATION 11 CONTACT CUSTOMER SUPPORT 12 2 C O N T E N T S IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY IFORMATION 4 INSTALLATION 5 SETUP MENU 7 1 PHASE CHARGE STATION 10 3 PHASE CHARGE STATION 11 SPECIFICATIONS 13 MAINTENANCE 13 FCC INFORMATION 14 WARRANTY INFORMATION 15 C O N T E N T S ...

Page 3: ...l suggestions Safety Guidelines Use this Home Box to charge electric vehicles equipped with a conductive charge port only See the vehicle s owner s handbook to determine if the vehicle is equipped with a conductive charge port Make certain the Home Box s supply cable is positioned so it will not be stepped on tripped over or otherwise subjected to damage or stress There are no user serviceable par...

Page 4: ...n your electrical cabinet and immediately contact Customer Support for service Do not use your Home Box until the problem is identified and corrected Caution Children should not be allowed to use this Home Box Do not allow children to play in or around the Home Box Close supervision of children is necessary when the Home Box is used Caution Do not open the enclosure Note This Home Box is designed ...

Page 5: ...e A 16A 3 Phase 5G2 50mm2 30mA Type 32A 1 Phase 3G6 00mm2 30mA Type A 32A 3 Phase 5G6 00mm2 For cable length upto 25m PLEASE NOTE All charges include an AC 30mA and DC 6mA residual current det ection Always place a type A RCD and the MCB or combination unit in the electrical cabinet 5 Open bottom cover of the Charge Station 5 screws see picture Carefully brake out required cable opening for incomi...

Page 6: ...hase L1 Brown N Blue Earth Green Yellow 3 Phase L1 Brown L2 Black L3 Grey N Blue Earth Green Yellow 8 Close bottom cover and carefully slide metallized cover over the Charge Station IMPORTANT OUTLET VERSION before closing outlet cover be sure the outlet is unlocked ...

Page 7: ...ation unit in the electrical cabinet 5 Open bottom cover of the Charge Station 5 screws see picture Carefully brake out required cable opening for incoming power cable and charge cable power cable from the back Use supplied M25 6 Use 4 wood screws M4 5x35mm to mount Charging Station on the wall The Charging Station should be installed between 0 80m and 1 20m from bottom to the ground HOME BOX PLUS...

Page 8: ...tion you can set the charging current to 16A FIXED 32 with this option you can set the charging current to 32A MANUAL you can adjust the charging current between 6A and 32A SMART not activated yet You can change the setup by pressing the left or right arrow button After your choice has been made confirm by pressing the middle button 2 SETUP I MIN SETUP I MIN Here you can set the minimum charging c...

Page 9: ...see picture Carefully brake out required cable opening for incoming power cable and charge cable power cable from the back Use supplied M25 6 Use 4 wood screws M4 5x35mm to mount Charging Station on the wall The Charging Station should be installed between 0 80m and 1 20m from bottom to the ground HOME BOX PLUS Version EV045 3 SETUP I MAX SETUP I MAX Here you can set the maximum charging current Y...

Page 10: ... button The menu below can be reached with the arrow button from a READY TO CHARGE screen but also from CHARGING screen Here you can find more information about the consumption I current A U voltage V P power kWh Et total kWh value cumulatieve you can t reset it By pressing the middle button you can see the meter readings of the last 5 sessions The values can be deleted by pressing the left and ri...

Page 11: ...lation 2 The electrical installation must be free of power during the entire installation period 3 Since this Charging Unit uses circuits that reference to ground no Megging must be done after connecting to power 4 Wiring and protection Version Wiring Mains Circuit Breaker MCB Residual Current Device RCD 16A 1 Phase 3G2 50mm2 30mA Type A 16A 3 Phase 5G2 50mm2 30mA Type 32A 1 Phase 3G6 00mm2 30mA T...

Page 12: ...ror code If multiple errors occur the codes will alternate By error massage please contact Ratio Electric for support Et 1 kWh Et 2 kWh Et 3 kWh Et 4 kWh Et 5 kWh CHARGER NOT READY ERRCODE 12 6 7 Connect in coming power to the left terminal block Single Phase L1 Brown N Blue Earth Green Yellow 3 Phase L1 Brown L2 Black L3 Grey N Blue Earth Green Yellow 8 Close bottom cover and carefully slide meta...

Page 13: ... M A I N T E N A N CE The Home Box requires no maintenance other than occasional cleaning Warning Switch off your Home Box before cleaning the unit Warning To reduce the risk of electrical shock or equipment damage be cautious while cleaning the connectors and case Clean the Home Box using a soft cloth lightly moistened with mild detergent solution Never use any type of abrasive pad scouring powde...

Page 14: ...there are some instances where high powered radio signals or nearby RF producing equipment such as digital phones RF communications equipment etc could affect operation If interference to your charge station is suspected we suggest the following steps be taken before consulting your Service Representative for assistance 1 Reorient or relocate nearby electrical appliances or equipment during chargi...

Page 15: ...15 W A R R A N T Y I N F O R M A T I O N HOME BOX PLUS Version EV045 ...

Page 16: ...16 C O N T A C T C U S T O M E R S U P P O R T Ratio Electric B V Ambachtsstraat 12 NL 3861 RH Nijkerk The Netherlands Tel 31 33 2452360 info ratio nl www ratio nl HOME BOX PLUS Version EV045 ...

Reviews: