Press briefly the middle button to start. After starting, the charger is always ready
to charge with the previous settings. If you want to change the settings enter the
setup menu (see page 7 SETUP MENU)
READY TO
CHARGE
You can reach the next screen with the left or right arrow button.
The menu’s below can be reached with the arrow button from a READY TO
CHARGE screen but also from CHARGING screen.
Here you can find more information about the consumption:
I:
current (A)
U:
voltage (V)
P:
power (kWh)
Et:
total kWh value
(cumulatieve,
you can’t reset it)
3 P H A S E C H A R G E S TAT I O N
I 1:
A
I 2:
A
I 3:
A
U 1:
V
U 2:
V
U 3:
V
P 1:
kWh
P 2:
kWh
P 3:
kWh
Et:
kWh
11
5
I N S T A L L A T I O N
1.
The installation must be done by a qualified and licenced electrician
according the local legislation.
2.
The electrical installation must be free of power during the entire
installation period.
3.
Since this Charging Unit uses circuits that reference to ground, no
Megging must be done after connecting to power.
4.
Wiring and protection:
Version
Wiring *
Mains Circuit Breaker
(MCB)
Residual Current Device
(RCD)
16A / 1 Phase
3G2,50mm
2
30mA, Type A
16A / 3 Phase
5G2,50mm
2
30mA, Type
32A / 1 Phase
3G6,00mm
2
30mA, Type A
32A / 3 Phase
5G6,00mm
2
*
For cable length upto 25m
PLEASE NOTE:
All charges include an AC (> 30mA) and
DC (> 6mA) residual-current-detection.
Always place a type A RCD and the MCB (or
combination unit) in the electrical cabinet.
5.
Open bottom cover of the Charge Station
(5 screws – see picture). Carefully brake out
required cable opening for incoming power cable
and charge cable.
power cable from the back. Use supplied M25
6.
Use 4 wood screws M4,5x35mm to mount Charging Station on the wall.
The Charging Station should be installed between 0,80m and 1,20m from
bottom to the ground.