10
6
7.
Connect in-coming power to the left
terminal block.
Single Phase :
L1=Brown
N= Blue
Earth= Green/Yellow
3 Phase
L1=Brown
L2=Black
L3=Grey
N=Blue
Earth=Green/Yellow
8.
Close bottom cover and carefully slide metallized cover over the Charge Station.
IMPORTANT:
OUTLET VERSION - before closing outlet cover,
be sure the outlet is unlocked!
Ratio ELECTRIC
www.ratio.nl
Press briefly the middle button to start. After starting, the charger is always ready
to charge with the previous settings. If you want to change the settings enter the
setup menu (see page 7 SETUP MENU)
READY TO
CHARGE
You can reach the next screen with the right arrow button.
The menu below can be reached with the arrow button from a READY TO
CHARGE screen but also from CHARGING screen.
Here you can find more information about the consumption:
I: current (A)
U: voltage (V)
P: power (kWh)
Et: total kWh value (cumulatieve, you can’t reset it)
By pressing the middle button, you can see the meter readings of the last 5
sessions.
The values can be deleted by pressing the left
and right arrow buttons at the same time.
With the middle button you can go back to the
previous screen.
CHARGER ERROR
In case of the charger error, you will see the
error screen with the error code. If multiple
errors occur the codes will alternate.
By error message please contact Ratio Electric
for support.
1 P H A S E C H A R G E S TAT I O N
I: A
U: V
P: kWh
Et: kWh
Et (1):
kWh
Et (2):
kWh
Et (3):
kWh
Et (4):
kWh
Et (5):
kWh
CHARGER
NOT READY
ERRCODE: …….