Testing of the Phone:

Push the silver emergency button on front of the Call Station:

 

Adjusting the Volume:

If the volume is too low or high, adjust it by referring to the diagram and instructions below.

*Note - Refer to the instructions under Programming the Phone to access the circuit board. 

               

Adjusting the Microphone:

If the person you are calling reports your voice is not loud enough, increase the Microphone Sensitivity by 

adjusting VR2 ¼ turn clockwise (requires a small Phillips screwdriver).

Adjusting the Speaker:

If the voice of the person you call is not loud enough in the emergency phone speaker, increase the 

Volume, by adjusting VR1 ¼ turn clockwise.

Reinstall the cover on the NEMA enclosure and secure the rear access panel.

Suggested Ongoing Testing of the Phone:

Rath recommends that the Emergency call stations be tested and maintained on a monthly basis to ensure 

proper operation. For testing, follow the procedure outlined in Testing of the Phone.

Do you hear a dial tone? 
Does the Strobe start flashing immediately when button was pushed?
Does red LED become a solid light when you pushed the button?
Does the red LED flash and a short time after (15-20 seconds) the called party started talking                            

to you? (Delay is due to phone telling other party your location via the “Location Message”)
Can you hear the other party clearly? (if no, see “Adjust Speaker” on the next page)
Can the other party hear you clearly? (If no, see “Adjust Microphone on the next page)
When the party you called hangs up, does the strobe stop?

                 Yes  No

If you have answered YES to all questions, you have successfully installed and tested your new 

emergency phone. If you answer no to any question, proceed to the Troubleshooting section.

Volume 

Adjust

VR1

Rath SmartPhone

Mic

Sensitivity

VR2

Summary of Contents for 2100-CPV

Page 1: ...Operations Manual C O M M U N I C A T I O N S E M E R G E N C Y N56 W24720 N Corporate Circle Sussex WI 53089 866 850 8854 262 246 4828 fax www rathsecurity com Made in the USA 2 Year Warranty 2100 C...

Page 2: ...ervice and support Our 1 mission is customer satisfaction When evaluating emergency communication systems you can rely on Rath to continually provide Innovative Thinking Design and Value Thank you for...

Page 3: ...ttach unit to pole using a secure mounting fastener 7 Connect the electrical conduit of the 110ac volt supply to the call station and run necessary wires 8 Connect the 110ac wiring to the call station...

Page 4: ...assem bly to the back panel install the top cap and reinstall the 12 screws to the sides of the unit Otherwise proceed to the directions for Programming the Phone On Site Wago Transformer Ground 10 c...

Page 5: ...ion message A To turn on message Press 1 3 Enter 2 B Press 6 Record speak message Stop to replay message Press 6 Play C For no message Press 1 3 Enter 0 Step 4 To exit program mode A Press Stop for 3...

Page 6: ...ted Ongoing Testing of the Phone Rath recommends that the Emergency call stations be tested and maintained on a monthly basis to ensure proper operation For testing follow the procedure outlined in Te...

Page 7: ...called party hangs up strobe continues to flash for 1 minute Slow disconnecting signal from the phone company This is considered normal operation When called party hangs up strobe continues to flash P...

Page 8: ...Tower Dimensional Specifications pg 7 C O M M U N I C A T I O N S E M E R G E N C Y 866 850 8854 www rathsecurity com Body of Tower Height 36 in Width 10 in Depth 8 in Thickness of Steel 18 gauge Wei...

Page 9: ...vered under this warranty Rath s liability under this warranty shall be solely limited to the repair or replacement of the defective parts within the warranty period and will not be liable under any c...